Experimental study of the “Mini-implant — bone tissue” model for a series of orthodontic mini-implants under quasi-static loading, provided that they are installed at an angle of 45° to the direction of force application
Oral and General Health · 20.04.2026 · 7 (1) · 16-20
DOI: 10.22141/ogh.7.1.2026.271 ↗Kurz gefasst
Fachartikel in der Zeitschrift Oral and General Health, online erschienen am 20.04.2026. Verfasst von L.G. Hryva und 1 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The use of orthodontic mini-implants is one of the most advanced directions in modern orthodontics, as they provide stable temporary skeletal anchorage and significantly expand the possibilities for controlling tooth movement. The application of mini-implants allows for complex orthodontic movements, such as distalization, mesialization, intrusion, and extrusion of teeth, while minimizing undesirable reactions from other dental units. Modern approaches to orthodontic treatment involve the use of various types of anchorage, including absolute, segmental, hybrid, and cortical one, which are determined by the clinical situation and treatment objectives. Mini-implants play a key role in implementing these approaches, ensuring a high level of control over orthodontic forces. At the same time, the effectiveness of mini-implant application depends on a number of factors, among which the mechanical properties of the “mini-implant — bone tissue” system are of particular importance. These characteristics include primary stability, pull-out resistance, fixation stiffness, as well as the influence of the implant’s geometric parameters and insertion conditions. The pre-sence of micromovements, variability in bone density, and anatomical limitations may negatively affect stability and long-term treatment outcomes. In this regard, experimental studies on the mechanical behavior of orthodontic mini-implants under various loading conditions are highly relevant. Particular attention is drawn to the analysis of their performance under inclined loading, which is closer to clinical application conditions. This study is aimed at determining the ultimate pull-out load and the stiffness of the “mini-implant — bone tissue” connection for a series of orthodontic mini-implants under quasi-static loading conditions when installed at an angle of 45° to the direction of force application.
Zitieren
APA
Hryva, L., & Musiienko, O. (2026). Experimental study of the “Mini-implant — bone tissue” model for a series of orthodontic mini-implants under quasi-static loading, provided that they are installed at an angle of 45° to the direction of force application. Oral and General Health, 7(1), 16-20. https://doi.org/10.22141/ogh.7.1.2026.271
Vancouver
Hryva L, Musiienko O. Experimental study of the “Mini-implant — bone tissue” model for a series of orthodontic mini-implants under quasi-static loading, provided that they are installed at an angle of 45° to the direction of force application. Oral and General Health. 2026;7(1):16-20. doi:10.22141/ogh.7.1.2026.271
BibTeX
@article{Hryva2026,
author = {Hryva, L.G. and Musiienko, O.S.},
title = {Experimental study of the “Mini-implant — bone tissue” model for a series of orthodontic mini-implants under quasi-static loading, provided that they are installed at an angle of 45° to the direction of force application},
journal = {Oral and General Health},
year = {2026},
volume = {7},
number = {1},
pages = {16--20},
doi = {10.22141/ogh.7.1.2026.271}
}
EUVIMED