EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Evaluation of Pain Intensity Caused by Nickel-Titanium Archwires of Different Sizes in the First Stage of Fixed Orthodontic Treatment: A Double-Blind Randomized Clinical Trial

Aydin Sohrabi, Shabnam Tahamtan, Sana Seyed Shariatdoust, Ali Rafighi

Journal of Mashhad Dental School · 2024-11 · 48 (4) · 913-924

DOI: 10.22038/jmds.2024.25223 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Mashhad Dental School, 2024-11. Verfasst von Aydin Sohrabi und 3 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Orthodontic treatment involves the use of archwires to apply force to teeth, which can cause pain and discomfort for the patient. Pain may be one of the most significant factors deterring patients from continuing orthodontic therapy. The aim of the present study was to comparatively assess pain induced by different-sized nickel-titanium archwires during the first stage of fixed orthodontic therapy.Methods and Materials: This double-blind randomized clinical trial included a total of 81 patients who received fixed orthodontic therapy. Patients were divided in to three equal groups according to the size of the utilized initial archwire (0.012, 0.014, and 0.016 inches). Perceived pain after archwire placement was evaluated using Visual Analogue Scale (VAS). Pain was assessed at three time points, immediately after bracket bonding (T1), 4 weeks (T2) and 8 weeks (T3) thereafter. Pain assessment at each time point was evaluated at four intervals- at placement, 3 hours, 24 hours, and 3 days after the placement of wire. The Repeated Measures ANOVA test was used to evaluate the effects of archwire size and time after placement on reported pain levels.

Results

The results showed that the pain reported in the superelastic nickel-titanium archwires of 0.012, 0.014, and 0.016 inches did not differ significantly from each other during the bonding session, 4 weeks, and 8 weeks after that (with p values of 0.404, 0.181, and 0.800, respectively). In other words, the size of the archwire did not affect the amount of pain caused. However, the intensity of pain over time at each of the mentioned intervals differed significantly (with p values of

Schlagwörter

fixed orthodontic appliancesorthodontic wirespainvisual analog scale

Zitieren

APA

Sohrabi, A., Tahamtan, S., Shariatdoust, S. S., & Rafighi, A. (2024). Evaluation of Pain Intensity Caused by Nickel-Titanium Archwires of Different Sizes in the First Stage of Fixed Orthodontic Treatment: A Double-Blind Randomized Clinical Trial. Journal of Mashhad Dental School, 48(4), 913-924. https://doi.org/10.22038/jmds.2024.25223

Vancouver

Sohrabi A, Tahamtan S, Shariatdoust SS, Rafighi A. Evaluation of Pain Intensity Caused by Nickel-Titanium Archwires of Different Sizes in the First Stage of Fixed Orthodontic Treatment: A Double-Blind Randomized Clinical Trial. Journal of Mashhad Dental School. 2024;48(4):913-924. doi:10.22038/jmds.2024.25223

BibTeX
@article{Sohrabi2024,
  author = {Sohrabi, Aydin and Tahamtan, Shabnam and Shariatdoust, Sana Seyed and Rafighi, Ali},