Study of Temperature Changes around Fibres in Super Pulse Thulium Fibre Laser in Vitro Lithotripsy.
Urology journal./Urology jornal. · 27.02.2023 · 20 (2) · 96-101
DOI: 10.22037/uj.v20i.7326 ↗Kurz gefasst
Fachartikel in der Zeitschrift Urology journal./Urology jornal., erschienen am 27.02.2023. Verfasst von Ding Tianfu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Tsinghua Changgung Hospital, Tsinghua University, Affiliated with the School of Clinical Medicine, Tsinghua University, Beijin…. Hauptthemen laut MEDLINE: Lasers, Solid-State, Lithotripsy, Laser. Die Arbeit wurde bisher 3-mal zitiert (Crossref).
Abstract (Originalsprache)
PURPOSE: To investigate temperature changes around the fibres of the super pulse thulium fibre laser (SP-TFL) during in vitro lithotripsy. MATERIALS AND METHODS: Stones were placed in the in vitro model. The laser was continuously excited for 180 s; the probe was positioned 5 mm around the fibre; the laser power was set at 10, 15, 20, 25, and 30 W; and the irrigation rate was set at 0, 15, 25, 35 ml/min, using a domestic SP-TFL. The temperature variations around the fibre under different power settings and different irrigation rates were compared. RESULTS: Without irrigation, the temperature around the fibre rapidly reached the safety threshold of 43℃ at 24 s. At irrigation rate 15 ml/min and laser power 43℃ at its lowest plateau. At irrigation rate 25 ml/min and laser power ≤25 W, the temperature around the fibre was 43℃. CONCLUSION: In extracorporeal ureteroscope SP-TFL lithotripsy, when the laser power is ≤15 W, ≤25 W, and ≤30 W, the irrigation rate should be maintained at ≥15 ml/min, ≥25 ml/min, and ≥35 ml/min, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Urology, Tsinghua Changgung Hospital, Tsinghua University, Affiliated with the School of Clinical Medicine, Tsinghua University, Beijing 102218.
- 1Department of Urology, Tsinghua Changgung Hospital, Tsinghua University, Affiliated with the School of Clinical Medicine, Tsinghua University, Beijing 102218. lijianxing2015@163.com.
Zitieren
APA
Tianfu, D., Bo, X., Xue, Z., Lei, L., Chaoyue, J., & Jianxing, L. (2023). Study of Temperature Changes around Fibres in Super Pulse Thulium Fibre Laser in Vitro Lithotripsy. Urology journal./Urology jornal., 20(2), 96-101. https://doi.org/10.22037/uj.v20i.7326
Vancouver
Tianfu D, Bo X, Xue Z, Lei L, Chaoyue J, Jianxing L. Study of Temperature Changes around Fibres in Super Pulse Thulium Fibre Laser in Vitro Lithotripsy. Urology journal./Urology jornal.. 2023;20(2):96-101. doi:10.22037/uj.v20i.7326
BibTeX
@article{Tianfu2023,
author = {Tianfu, Ding and Bo, Xiao and Xue, Zeng and Lei, Liang and Chaoyue, Ji and Jianxing, Li},
title = {Study of Temperature Changes around Fibres in Super Pulse Thulium Fibre Laser in Vitro Lithotripsy},
journal = {Urology journal./Urology jornal.},
year = {2023},
volume = {20},
number = {2},
pages = {96--101},
doi = {10.22037/uj.v20i.7326}
}
EUVIMED