EUVIMEDScopri EUVIMED
Crossref

Feasibility and Adherence of a Multicomponent Digital Health Monitoring Platform in Ambulatory Heart Failure: Multicenter Observational Study

Christopher J McLeod, Charles Bruce, Kuldeep Singh Rajput, Joseph S Ross, Sy Jackie Lou Velarde, Felis Dwiyasa, Chen Hao, Yan He, Stephanie Zawada, Maulik Majmudar

JMIR Formative Research · 2026-11-19 · 10 · e99974

DOI: 10.2196/99974 ↗

At a glance

Journal article in JMIR Formative Research, published online on 2026-11-19. Written by Christopher J McLeod and 9 co-authors. 33 references.

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Digital health platforms combining wearable biosensors with smartphone apps offer scalable approaches to heart failure (HF) management, yet sustained patient engagement and initial technology adoption, particularly among older adults, remain uncertain.

Objective

We conducted a prospective, multicenter observational study to explore the feasibility and adherence of using a digital health monitoring platform for 8 weeks in a population of ambulatory patients with HF.

Methods

In this prospective multicenter observational study, patients with New York Heart Association (NYHA) class I to III HF were prescreened across 6 institutions in the United States and Singapore. Participants wore an Everion multisensor armband and an Apple Watch continuously and completed daily electrocardiograms (ECGs), daily symptom questionnaires, weekly voice recordings, and biweekly KCCQ-12 (Kansas City Cardiomyopathy Questionnaire-12) assessments. Prespecified end points included recruitment yield, device wear-time, task-specific compliance, dropout rate, and adverse events.

Results

Of 3386 prescreened individuals, 520 (15.4%) were clinically eligible; 66 consented (1.9% of prescreened; 12.7% of eligible), with technology-related concerns driving most declinations. Among 65 enrolled patients (mean age 56.5, SD 12.3 years; n=53, 81.5% male), 52 (80%) completed 8 weeks. Mean daily wear-time was 11.7 (SD 5.7) hours, significantly exceeding the 8-hour benchmark (P

Cite

APA

McLeod, C. J., Bruce, C., Rajput, K. S., Ross, J. S., Velarde, S. J. L., Dwiyasa, F., Hao, C., He, Y., Zawada, S., & Majmudar, M. (2026). Feasibility and Adherence of a Multicomponent Digital Health Monitoring Platform in Ambulatory Heart Failure: Multicenter Observational Study. JMIR Formative Research, 10, e99974. https://doi.org/10.2196/99974

Vancouver

McLeod CJ, Bruce C, Rajput KS, Ross JS, Velarde SJL, Dwiyasa F, et al. Feasibility and Adherence of a Multicomponent Digital Health Monitoring Platform in Ambulatory Heart Failure: Multicenter Observational Study. JMIR Formative Research. 2026;10:e99974. doi:10.2196/99974

BibTeX
@article{McLeod2026,
  author = {McLeod, Christopher J and Bruce, Charles and Rajput, Kuldeep Singh and Ross, Joseph S and Velarde, Sy Jackie Lou and Dwiyasa, Felis and Hao, Chen and He, Yan and Zawada, Stephanie and Majmudar, Maulik},
  title = {Feasibility and Adherence of a Multicomponent Digital Health Monitoring Platform in Ambulatory Heart Failure: Multicenter Observational Study},
  journal = {JMIR Formative Research},
  year = {2026},
  volume = {10},
  pages = {e99974},
  doi = {10.2196/99974}
}
Start for free →