Data Stream and Hospital-Level Variation in Intensive Care Unit Vital-Sign Record Density Across Medical Information Mart for Intensive Care IV and eICU Collaborative Research Database: Retrospective Data Quality Study
Datenstrom und Krankenhausunterschiede in der Dichte von Vitalzeichenaufzeichnungen auf Intensivstationen in MIMIC-IV und eICU-CRD: retrospektive Datenqualitätsstudie
JMIR Medical Informatics · 2026-10-29 · 14 · e99638
DOI: 10.2196/99638 ↗Auf einen Blick
In zwei Intensivdatenbanken variierte die Dichte von Vitalzeichenaufzeichnungen stärker zwischen beitragenden Häusern als zwischen Stationen innerhalb eines Hauses. Unterschiede zwischen Datenbanken hingen auch von der gewählten Quelle ab.
Fragestellung
Variiert die Dichte von Vitalzeichenaufzeichnungen primär nach Datenstrom, Datenbank, beitragendem Standort oder Care Unit, und was folgt daraus für Vergleiche?
Methode
Retrospektive Analyse von MIMIC-IV 3.1 und eICU-CRD 2.0; Auswertung der ersten 24 Intensivstunden; Varianzzerlegung mit η2, hospital-geclusterter Bootstrap-Inferenz und Mixed-Effects-Sensitivitätsanalysen.
Ergebnisse
In 117.572 eICU-CRD-Aufenthalten waren pflege- und monitorbasierte Zählungen nahezu unkorreliert (Spearman ρ=0,024). Für die Zählung betrug η2 auf Krankenhausebene 0,354 (95 %-KI 0,259–0,450) und innerhalb des Hauses 0,043; in MIMIC-IV lagen zwischen den Datenbanken große Unterschiede vor.
Einschränkungen
8 von 68 eICU-CRD-Krankenhäusern lagen unter der Plausibilitätsgrenze und wurden aus der Hauptanalyse ausgeschlossen; diese Restriktion wurde während der Begutachtung eingeführt.
Schlussfolgerung der Autor:innen
Innerhalb eines multisite pflegebasierten Streams variierte das Aufkommen von Vitalzeichenaufzeichnungen stärker zwischen den Standorten als zwischen Care Units. Für Vergleiche müssen Stream, Analysefenster und Standortvariation explizit berücksichtigt werden.
Kernaussagen
- Pflege- und monitorbasierte Zählungen waren kaum miteinander verknüpft.
- Die Krankenhauskomponente der Zählung war größer als die Unit-Komponente.
- Vergleiche brauchen die Spezifikation des erzeugenden Streams und der Standortvariation.
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
At a glance
Journal article in JMIR Medical Informatics, published online on 2026-10-29. Written by Yngve Mikkelsen. Institution: Saïd Business School, University of Oxford, Oxford, England, United Kingdom. Major MEDLINE topics: Intensive Care Units, Electronic Health Records, Vital Signs, Data Accuracy. Cited 1 times so far (Crossref); 23 references. The full text is freely available in PubMed Central.
Topics: Intensivpflege
Abstract (original language)
Background
Electronic health record–derived process measures such as vital-sign record density are used for quality monitoring, risk prediction, and cross-system benchmarking, but whether they retain consistent meaning across sites and data streams is rarely tested.
Objective
This study aimed to determine whether vital-sign record density varies primarily by data stream, database, contributing site, or care unit, and what follows for comparative use.
Methods
We retrospectively analyzed the Medical Information Mart for Intensive Care IV (MIMIC-IV) version 3.1 and the eICU Collaborative Research Database (eICU-CRD) version 2.0. Record density and timing metrics were computed for the first 24 intensive care unit hours from nurse-charted streams and, in eICU-CRD, from the monitor stream. Heart rate was primary; oxygen saturation and respiratory rate were replication variables. Variance was decomposed by database, hospital, and unit using η2 with hospital-clustered bootstrap inference and mixed-effects sensitivity analyses. A hospital-level plausibility floor of 12 nurse-charted heart rate observations per 24 hours was applied for the principal analysis; unrestricted and alternative-floor analyses are reported as sensitivities.
Results
A pooled-item MIMIC-IV heart rate count included alarm-limit documentation events, so label-based pooling mixes the two. In 117,572 eICU-CRD stays present in both streams, nurse- and monitor-derived counts were almost unrelated (Spearman ρ=0.024), with bottom-decile overlap at chance. Between-database η2 for record count was 0.960 against the eICU monitor stream and 0.026 against the nurse stream. Eight of 68 eICU-CRD hospitals fell below the plausibility floor and were excluded from principal estimates, a restriction introduced during review. Among the remaining 60 hospitals (88,560 stays), hospital η2 for record count was 0.354 (95% CI 0.259-0.450) against unit-within-hospital η2 of 0.043; for the interval-structure metrics, the hospital and unit components were not separable. For record count, the hospital component fell from 0.441 unrestricted to 0.321 at an hourly floor. A negative-binomial mixed model gave latent-scale hospital and unit variance-partition coefficients of 0.348 (95% CI 0.252-0.457) and 0.112 (0.078-0.163), equivalent to 0.318 and 0.110 observed. A pooled bottom-decile rule agreed with hospital-specific rules on 52.5% (4726/9006) of flagged stays, with 6 hospitals supplying half the pooled decile. The hospital component for record count replicated at 0.322 for oxygen saturation and 0.333 for respiratory rate.
Conclusions
Within a multisite nurse-charted stream, vital-sign record volume varied more across contributing sites than across care units within hospitals; for the interval-structure metrics, the site and unit components were not separable at this cohort size. Apparent cross-database differences were reproduced by source-table choice, and site-level variation remained after excluding the most evident contribution-completeness outliers. Comparative use therefore requires specifying the generating stream, enforcing the analytic window, and explicitly modeling site-level variation; the residual site component should not be interpreted as documentation practice alone.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Saïd Business School, University of Oxford, Oxford, England, United Kingdom.
ORCID profiles: Yngve Mikkelsen
Cite
APA
Mikkelsen, Y. (2026). Data Stream and Hospital-Level Variation in Intensive Care Unit Vital-Sign Record Density Across Medical Information Mart for Intensive Care IV and eICU Collaborative Research Database: Retrospective Data Quality Study. JMIR Medical Informatics, 14, e99638. https://doi.org/10.2196/99638
Vancouver
Mikkelsen Y. Data Stream and Hospital-Level Variation in Intensive Care Unit Vital-Sign Record Density Across Medical Information Mart for Intensive Care IV and eICU Collaborative Research Database: Retrospective Data Quality Study. JMIR Medical Informatics. 2026;14:e99638. doi:10.2196/99638
BibTeX
@article{Mikkelsen2026,
author = {Mikkelsen, Yngve},
title = {Data Stream and Hospital-Level Variation in Intensive Care Unit Vital-Sign Record Density Across Medical Information Mart for Intensive Care IV and eICU Collaborative Research Database: Retrospective Data Quality Study},
journal = {JMIR Medical Informatics},
year = {2026},
volume = {14},
pages = {e99638},
doi = {10.2196/99638}
}
EUVIMED