EUVIMEDOpdag EUVIMED
Mixed-Methods-StudieOpen access

Real-World Health Monitoring Using Wrist-Worn Wearables in Community-Dwelling Older Adults in China: Mixed Methods Feasibility Study

Real-World-Health-Monitoring mit am Handgelenk getragenen Wearables bei älteren Erwachsenen in der Gemeinschaft in China: Mixed-Methods-Feasibility-Studie

Ying Bai, Yi Tang, Yiwei Zhao, Lixin Ma, Yanjun Ma, Zhibin Wang

JMIR Human Factors · 2026-10-29 · 13 · e98592-e98592

DOI: 10.2196/98592 ↗

Auf einen Blick

Bei 486 älteren Erwachsenen in China war das Tragen eines Wrist-Wearables unter Alltagsbedingungen für einen relevanten Teil machbar. Die Nutzerbewertung war insgesamt günstig.

Fragestellung

Wie machbar, benutzbar und akzeptabel ist ein am Handgelenk getragenes Wearable zur kontinuierlichen Erfassung von Verhalten und Physiologie bei älteren Erwachsenen in China?

Methode

486 community-dwelling older adults aus der Beijing-Region erhielten ein Huawei Band 8. Erfasst wurden Monitoring-Muster, Gesundheits- und Funktionsdaten sowie eine Nutzererhebung.

Ergebnisse

224/486 (46,1 %) erreichten ≥3 aufeinanderfolgende gültige Monitoring-Tage, 156/486 (32,1 %) nicht aufeinanderfolgende und 106/486 (21,8 %) keinen gültigen Tag. Die Nutzererhebung wurde von 106/486 (21,8 %) ausgefüllt.

Einschränkungen

Monitoring-Muster variierten erheblich zwischen Personen; Stabilität und klinische Relevanz der Wearable-Maße über längere Zeit sind ungeklärt.

Schlussfolgerung der Autor:innen

Die Autoren berichten, dass Wrist-Wearable-Monitoring unter Alltagsbedingungen für einen erheblichen Teil älterer Erwachsener in China machbar war; größere und längerfristige Implementierung bleibt herausfordernd.

Kernaussagen

  • 46,1 % erreichten ≥3 aufeinanderfolgende gültige Monitoring-Tage
  • Nutzerfeedback überwiegend günstig; Barrieren: Unbehagen, Synchronisation, Akku
  • Weitere Forschung zu Stabilität und klinischer Relevanz ist nötig

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

At a glance

Mixed-Methods-Studie in JMIR Human Factors, published online on 2026-10-29. Written by Ying Bai and 5 co-authors. Institution: Department of Neurology & Innovation Center for Neurological Disorders, Xuanwu Hospital, Capital Medical University, National Center for Neurological…. Major MEDLINE topics: Wearable Electronic Devices, Independent Living. Cited 1 times so far (Crossref); 55 references. The full text is freely available in PubMed Central.

Auf einen BlickAbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Real-world behavioral and physiological functioning, including heart rate, daily mobility, and sleep patterns, may provide information about aging and early neurodegenerative changes that is not captured by periodic clinical visits. Wrist-worn wearable devices offer a promising approach for continuous, passive monitoring of these domains. However, evidence regarding feasibility, usability, and acceptability in real-world observational settings among community-dwelling older adults in China remains limited.

Objective

This study primarily aimed to evaluate the feasibility, usability, and acceptability of using wrist-worn wearable devices to monitor behavioral and physiological function in community-dwelling older adults under naturalistic conditions. As a secondary objective, the study descriptively characterized wearable-derived behavioral and physiological measures among participants with minimal consecutive valid monitoring.

Methods

We enrolled 486 community-dwelling older adults from the Beijing region of the China-Aging cohort, each of whom received a Huawei Band 8 commercial wrist-worn wearable device. A valid monitoring day was defined as 10 or more hours of wear time. Participants were classified into three monitoring-pattern categories based on predefined wear-time criteria: no valid monitoring day, nonconsecutive valid monitoring, and minimal consecutive valid monitoring (≥3 consecutive valid monitoring days). Demographic characteristics, health status, and cognitive and functional measures (Mini-Mental State Examination and Barthel Activities of Daily Living Index) were compared across groups. Usability, acceptability, and perceived barriers were assessed using a structured user experience survey.

Results

Of 486 participants, 224 (46.1%) achieved minimal consecutive valid monitoring, 156 (32.1%) had nonconsecutive valid monitoring, and 106 (21.8%) had no valid monitoring day. Self-rated health differed significantly across monitoring patterns ( P =.005), whereas no significant differences were observed for the other measured baseline characteristics. Among participants with minimal consecutive valid monitoring, mean daily heart rate was 72.1 (SD 8.6) bpm, median daily step count was 6177 (IQR 4249‐8872) steps/day, and sleep data were available for 211 out of 224 (94.2%), with a median sleep duration of 7.23 (IQR 6.48‐8.04) hours. The user experience survey was completed by 106 out of 486 (21.8%) participants, with higher participation among those with more sustained monitoring. Respondents generally reported favorable usability and acceptability; common barriers included device discomfort, data synchronization issues, and battery life.

Conclusions

Wrist-worn wearable monitoring was feasible under naturalistic conditions for a substantial proportion of community-dwelling older adults in China, with generally favorable usability and acceptability among survey respondents. However, monitoring patterns varied considerably across individuals, highlighting challenges for long-term use and large-scale implementation. These findings support the potential of wearable technologies for longitudinal monitoring outside clinic-based assessments. Further research is needed to establish the stability and clinical relevance of wearable-derived behavioral measures over longer monitoring periods.

Subjects

MeSH terms (MEDLINE)

Wearable Electronic DevicesIndependent LivingHumansFemaleMaleAgedFeasibility StudiesChinaAged, 80 and overMonitoring, PhysiologicDigital HealthWrist

Author keywords

Chinaacceptabilitydigital healthfeasibilityolder adultsusabilitywearable devices

Authors and institutions

  • Department of Neurology & Innovation Center for Neurological Disorders, Xuanwu Hospital, Capital Medical University, National Center for Neurological Disorders, 45 Changchun Street, Xicheng District, Beijing, 100053, Ch…
  • Beijing Key Laboratory of Digital Medicine for Cognitive Disorders, Beijing, China.
  • Department of Neurology, The First Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.
  • Xuanwu Hospital, Capital Medical University, National Center for Neurological Disorders, Beijing, China.

Cite

APA

Bai, Y., Tang, Y., Zhao, Y., Ma, L., Ma, Y., & Wang, Z. (2026). Real-World Health Monitoring Using Wrist-Worn Wearables in Community-Dwelling Older Adults in China: Mixed Methods Feasibility Study. JMIR Human Factors, 13, e98592-e98592. https://doi.org/10.2196/98592

Vancouver

Bai Y, Tang Y, Zhao Y, Ma L, Ma Y, Wang Z. Real-World Health Monitoring Using Wrist-Worn Wearables in Community-Dwelling Older Adults in China: Mixed Methods Feasibility Study. JMIR Human Factors. 2026;13:e98592-e98592. doi:10.2196/98592

BibTeX
@article{Bai2026,
  author = {Bai, Ying and Tang, Yi and Zhao, Yiwei and Ma, Lixin and Ma, Yanjun and Wang, Zhibin},
  title = {Real-World Health Monitoring Using Wrist-Worn Wearables in Community-Dwelling Older Adults in China: Mixed Methods Feasibility Study},
  journal = {JMIR Human Factors},
  year = {2026},
  volume = {13},
  pages = {e98592--e98592},
  doi = {10.2196/98592}
}
Start for free →