EUVIMEDSkopri EUVIMED
Systematische ÜbersichtMetaanalyseÜbersichtsarbeitOpen access

Diagnostic Accuracy of Medical Imaging–Based Artificial Intelligence for Osteonecrosis of the Femoral Head: Systematic Review and Meta-Analysis

Diagnostische Genauigkeit bildgebungsbasierter KI für die Osteonekrose des Femurkopfs: systematische Übersicht und Metaanalyse

FeiLong Lu, LiRong Wang, Wenbin Zhang, YuLin Ma, JingYuan Tian, YiMei Hu

Journal of Medical Internet Research · 2026-08-20 · 28 · e95648-e95648

DOI: 10.2196/95648 ↗

Auf einen Blick

12 Studien zeigen für bildgebungsbasierte KI bei der Diagnose der Osteonekrose des Femurkopfs eine hohe diagnostische Genauigkeit. Die AUC lag bei 0,97.

Fragestellung

Wie genau diagnostizieren medizinische Bildgebungs-KI-Modelle die Osteonekrose des Femurkopfs?

Methode

Systematische Übersichtsarbeit und Metaanalyse nach PRISMA-DTA; Suche in PubMed, Embase, Cochrane Library und Web of Science bis 8. März 2026; QUADAS-2-Bewertung.

Ergebnisse

12 Studien mit 16.189 Hüftgelenken. Gepoolte Sensitivität 0,91 (95 %-KI 0,87–0,95), Spezifität 0,95 (95 %-KI 0,93–0,96), SROC-AUC 0,97 (95 %-KI 0,95–0,98). Heterogenität hoch (I²=72%).

Einschränkungen

Begrenzte Zahl eingeschlossener Studien, überwiegend retrospektive Designs und unzureichende externe Validierung.

Schlussfolgerung der Autor:innen

KI-Modelle zeigten eine hohe diagnostische Genauigkeit bei bildgebungsbasierter Diagnose der ONFH, die Evidenz sollte wegen der genannten Einschränkungen jedoch mit Vorsicht interpretiert werden.

Kernaussagen

  • Sensitivität 0,91 und Spezifität 0,95
  • SROC-AUC 0,97
  • Bildgebungsart als Hauptquelle der Heterogenität

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

At a glance

Systematische Übersicht in Journal of Medical Internet Research, published online on 2026-08-20. Written by FeiLong Lu and 5 co-authors. Institution: School of Clinical Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan, China. Major MEDLINE topics: Artificial Intelligence, Femur Head Necrosis. Cited 1 times so far (Crossref); 51 references. The full text is freely available in PubMed Central.

Auf einen BlickAstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Osteonecrosis of the femoral head (ONFH) is a common cause of hip disability in clinical practice. Early and accurate diagnosis can delay or even halt disease progression. In recent years, AI models based on medical imaging have been increasingly applied to the diagnosis of ONFH; however, a systematic evaluation of their diagnostic accuracy remains lacking.

Objective

This study aims to synthesize the overall diagnostic accuracy of medical imaging-based AI models for ONFH and to inform clinical decision-making.

Methods

This systematic review was conducted in accordance with the PRISMA-DTA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy Studies) guidelines and was prospectively registered in PROSPERO (CRD420261307216). We searched PubMed, Embase, Cochrane Library, and Web of Science up to March 8, 2026. Studies developing or validating AI models for ONFH diagnosis using imaging data were eligible. Risk of bias was assessed using the QUADAS-2 tool. Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were pooled using a bivariate mixed-effects model, and a summary receiver operating characteristic (SROC) curve was constructed. Subgroup analyses were stratified by imaging modality (x-ray vs MRI), disease stage (early-stage ONFH vs all-stage ONFH), diagnostic criteria (Association Research Circulation Osseous [ARCO] staging vs other criteria), control group type (healthy controls vs disease controls), validation method (internal validation vs external validation), center type (single-center vs multicenter), and model type (deep learning vs machine learning). Meta-regression was performed to quantify the contribution of each covariate to between-study heterogeneity. Sensitivity analysis and Deeks asymmetry test assessed the robustness of the results and publication bias. Clinical utility was evaluated using the Fagan nomogram.

Results

A total of 12 studies comprising 16,189 hip joints were included. The pooled sensitivity was 0.91 (95% CI 0.87‐0.95), the pooled specificity was 0.95 (95% CI 0.93‐0.96), and the SROC AUC was 0.97 (95% CI 0.95‐0.98). Substantial between-study heterogeneity was observed ( I ²=72%, 95% CI 38%‐100%). Subgroup analysis showed that MRI-based models yielded a higher diagnostic odds ratio (DOR; 382, 95% CI 220‐665) than x-ray-based models (106, 95% CI 60‐190), while models that underwent external validation had a lower DOR (129, 95% CI 51‐329) than those with only internal validation (230, 95% CI 104‐510). Meta-regression identified imaging modality as the primary source of heterogeneity, explaining 92.1% of the between-study variance.

Conclusions

AI models demonstrate high diagnostic accuracy in imaging-based ONFH diagnosis. However, the current evidence is constrained by the limited number of included studies, predominantly retrospective designs, and a lack of adequate external validation, and should therefore be interpreted with caution. Future research should adopt multicenter prospective designs, standardize reference standards, and implement rigorous external validation to facilitate clinical translation.

Subjects

MeSH terms (MEDLINE)

Artificial IntelligenceFemur Head NecrosisHumansSensitivity and Specificity

Author keywords

artificial intelligencedeep learningdiagnostic imagingmachine learningmeta-analysisosteonecrosis of the femoral head

Authors and institutions

  • School of Clinical Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu, Sichuan, China.
  • Department of Orthopedics, Qionglai Hospital of Traditional Chinese Medicine, Qionglai, Sichuan, China.
  • Department of Orthopedics, Affiliated Hospital of Chengdu University of Traditional Chinese Medicine, 37 Shi'erqiao Road, Chengdu, Sichuan Province, 610075, China, 86 18908041502.

Cite

APA

Lu, F., Wang, L., Zhang, W., Ma, Y., Tian, J., & Hu, Y. (2026). Diagnostic Accuracy of Medical Imaging–Based Artificial Intelligence for Osteonecrosis of the Femoral Head: Systematic Review and Meta-Analysis. Journal of Medical Internet Research, 28, e95648-e95648. https://doi.org/10.2196/95648

Vancouver

Lu F, Wang L, Zhang W, Ma Y, Tian J, Hu Y. Diagnostic Accuracy of Medical Imaging–Based Artificial Intelligence for Osteonecrosis of the Femoral Head: Systematic Review and Meta-Analysis. Journal of Medical Internet Research. 2026;28:e95648-e95648. doi:10.2196/95648

BibTeX
@article{Lu2026,
  author = {Lu, FeiLong and Wang, LiRong and Zhang, Wenbin and Ma, YuLin and Tian, JingYuan and Hu, YiMei},
  title = {Diagnostic Accuracy of Medical Imaging–Based Artificial Intelligence for Osteonecrosis of the Femoral Head: Systematic Review and Meta-Analysis},
  journal = {Journal of Medical Internet Research},
  year = {2026},
  volume = {28},
  pages = {e95648--e95648},
  doi = {10.2196/95648}
}
Start for free →