Feasibility Assessment of Smartphone Camera–Based Atrial Fibrillation Detection Compared With Portable Electrocardiogram: Single-Patient Case Study
JMIR Formative Research · 13.11.2026 · 10 · e94661
DOI: 10.2196/94661 ↗Kurz gefasst
Fallbericht in der Zeitschrift JMIR Formative Research, online erschienen am 13.11.2026. Verfasst von Bipin Patel und 4 weiteren Autor:innen. Beteiligte Einrichtung: electronRx Ltd, Cambridge, Cambridgeshire, United Kingdom. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electrocardiography, Photoplethysmography, Smartphone. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
Atrial fibrillation (AF) affects more than 33 million people globally, with many cases remaining undiagnosed due to the paroxysmal nature of the condition. Current portable AF detection devices require additional hardware, and their cost may limit their accessibility in community screening programs. Facial camera–based remote photoplethysmography (rPPG) is a novel alternative to conventional fingertip-based photoplethysmography (PPG) that enables contact-free cardiac rhythm assessment.
Objective
This study aimed to assess the technical feasibility of a novel smartphone camera–based facial rPPG AF detection system by comparing its performance with that of a portable electrocardiogram (ECG) device under real-world home monitoring conditions.
Methods
We conducted a prospective, single-patient volunteer case study involving a patient with diagnosed paroxysmal AF and atrial flutter with variable block over 12 consecutive days. Simultaneous 60-second recordings were scheduled 3 times daily using the electronRx smartphone app and a Kardia portable ECG device to obtain a total of 36 paired recordings. The primary outcome was device agreement in rhythm classification between the 2 systems. Secondary outcomes included assessment of the effect of signal quality on device agreement and analysis of discordant recordings to identify technical limitations.
Results
Of the 36 scheduled recording sessions, 35 were attempted, yielding 24 successful simultaneous recordings. Of these, 23 paired recordings met the quality criteria, and device agreement was achieved in 21 (91.3%) recordings. The smartphone system detected 4 of the 5 episodes classified as AF by the Kardia device and agreed with 17 of the 18 recordings classified as normal sinus rhythm. A total of 2 discordant cases were identified: 1 false negative associated with atrial flutter presenting as a fixed 3:1 atrioventricular block and 1 false positive related to poor signal quality due to suboptimal lighting conditions. Signal quality significantly affected performance, with 94.7% agreement in recordings of good quality compared with 75% in recordings of poor quality.
Conclusions
This case study demonstrates the technical feasibility of using a smartphone facial camera–based rPPG rhythm analysis for AF detection. The approach shows promise as an accessible screening tool. However, the single-patient design, data attrition resulting from synchronization and signal quality issues, and the identified technical limitations highlight the need for larger validation studies before clinical application can be considered.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- electronRx Ltd, Cambridge, Cambridgeshire, United Kingdom.
- Trinity Court Surgery, Stratford Upon Avon, Warwickshire, United Kingdom.
- Queen Elizabeth Hospital, University of Birmingham, Birmingham, United Kingdom.
ORCID-Profile: Bipin Patel, David Buckley, Garth Cruickshank, Claire Ginn, Lucas Mogg
Zitieren
APA
Patel, B., Buckley, D., Cruickshank, G., Ginn, C., & Mogg, L. (2026). Feasibility Assessment of Smartphone Camera–Based Atrial Fibrillation Detection Compared With Portable Electrocardiogram: Single-Patient Case Study. JMIR Formative Research, 10, e94661. https://doi.org/10.2196/94661
Vancouver
Patel B, Buckley D, Cruickshank G, Ginn C, Mogg L. Feasibility Assessment of Smartphone Camera–Based Atrial Fibrillation Detection Compared With Portable Electrocardiogram: Single-Patient Case Study. JMIR Formative Research. 2026;10:e94661. doi:10.2196/94661
BibTeX
@article{Patel2026,
author = {Patel, Bipin and Buckley, David and Cruickshank, Garth and Ginn, Claire and Mogg, Lucas},
title = {Feasibility Assessment of Smartphone Camera–Based Atrial Fibrillation Detection Compared With Portable Electrocardiogram: Single-Patient Case Study},
journal = {JMIR Formative Research},
year = {2026},
volume = {10},
pages = {e94661},
doi = {10.2196/94661}
}
EUVIMED