Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation
Europace · 30.03.2024 · 26 (4)
DOI: 10.1093/europace/euae065 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 17.04.2024. Verfasst von Henri Gruwez und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ziekenhuis Oost-Limburg, Synaps Park 1, 3600 Genk, Belgium. Hauptthemen laut MEDLINE: Atrial Fibrillation. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific Research Flanders, Qompium NV.
Abstract (Originalsprache)
Aims
Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. Methods and results Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7–99.9%], specificity (99.9%; CI: 99.8–100.0%), positive predictive value (99.6%; CI: 99.1–100.0%), and negative predictive value (99.6%; CI: 99.0–100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland–Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m.
Conclusion
Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Ziekenhuis Oost-Limburg, Synaps Park 1, 3600 Genk, Belgium.
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
- Limburg Clinical Research Center, Faculty of Medicine and Life Sciences, Hasselt University, Martelarenlaan 42, 3500 Hasselt, Belgium.
- Research Institute Center for Statistics (CENSTAT), Hasselt University, Hasselt, Belgium.
ORCID-Profile: Henri Gruwez, Daniel Ezzat, Tim Van Puyvelde, Sebastiaan Dhont, Evelyne Meekers, Liesbeth Bruckers, Femke Wouters, Michiel Kellens, Hugo Van Herendael, Maximo Rivero-Ayerza, Dieter Nuyens, Peter Haemers, Laurent Pison
Förderung
- Scientific Research Flanders
- Qompium NV
Zitieren
APA
Gruwez, H., Ezzat, D., Van Puyvelde, T., Dhont, S., Meekers, E., Bruckers, L., Wouters, F., Kellens, M., Van Herendael, H., Rivero-Ayerza, M., Nuyens, D., Haemers, P., & Pison, L. (2024). Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation. Europace, 26(4). https://doi.org/10.1093/europace/euae065
Vancouver
Gruwez H, Ezzat D, Van Puyvelde T, Dhont S, Meekers E, Bruckers L, et al. Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation. Europace. 2024;26(4). doi:10.1093/europace/euae065
BibTeX
@article{Gruwez2024,
author = {Gruwez, Henri and Ezzat, Daniel and Van Puyvelde, Tim and Dhont, Sebastiaan and Meekers, Evelyne and Bruckers, Liesbeth and Wouters, Femke and Kellens, Michiel and Van Herendael, Hugo and Rivero-Ayerza, Maximo and Nuyens, Dieter and Haemers, Peter and Pison, Laurent},
title = {Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation},
journal = {Europace},
year = {2024},
volume = {26},
number = {4},
doi = {10.1093/europace/euae065}
}
EUVIMED