Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis
Journal of Medical Internet Research · 11.09.2026 · 28 · e92399-e92399
DOI: 10.2196/92399 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Medical Internet Research, online erschienen am 11.09.2026. Verfasst von Yujia Lv und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology and Health Statistics, School of Public Health, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, …. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Artificial Intelligence, Mass Screening. Die Arbeit nennt 108 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Obstructive sleep apnea (OSA) is highly prevalent but remains substantially underdiagnosed. Polysomnography (PSG) is the reference standard, but its cost and limited availability constrain large-scale case identification. AI-based screening tools may support risk stratification and referral prioritization, but their diagnostic accuracy across apnea-hypopnea index (AHI) thresholds remains uncertain.
Objective
This review aimed to systematically evaluate the diagnostic accuracy of AI-based OSA screening tools at AHI thresholds of ≥5, ≥15, and ≥30 events/hour, with emphasis on models using non-PSG–derived inputs.
Methods
PubMed, Embase, Scopus, and Web of Science were searched for studies published from January 1, 2016, to May 3, 2026. Eligible studies included adults evaluated for suspected OSA or recruited from population-based cohorts, assessed AI-based models intended or interpretable for OSA screening, risk prediction, or screening-oriented severity classification, used PSG as the reference standard, and reported sufficient data to construct or reconstruct 2×2 contingency tables. Diagnostic accuracy was synthesized separately by AHI threshold and input source using bivariate random-effects models, with 95% CIs and prediction intervals (PIs). Risk of bias and certainty of evidence were assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) and GRADE (Grading of Recommendations Assessment, Development, and Evaluation), respectively.
Results
A total of 60 studies were included, of which 47 contributed data to the meta-analysis. At AHI thresholds of ≥5, ≥15, and ≥30 events/hour, pooled sensitivities were 0.94 (95% CI 0.92‐0.96; 95% PI 0.71‐0.99), 0.87 (95% CI 0.84‐0.89; 95% PI 0.66‐0.96), and 0.83 (95% CI 0.79‐0.87; 95% PI 0.61‐0.94), respectively; the corresponding specificities were 0.77 (95% CI 0.69‐0.84; 95% PI 0.30‐0.96), 0.81 (95% CI 0.75‐0.85; 95% PI 0.39‐0.96), and 0.91 (95% CI 0.87‐0.94; 95% PI 0.55‐0.99), respectively. The corresponding areas under the summary receiver operating characteristic curves were 0.943, 0.907, and 0.920. For non-PSG–derived tools, sensitivities were 0.92, 0.85, and 0.81, and specificities were 0.70, 0.74, and 0.85 at the 3 thresholds, respectively. For PSG-derived models, sensitivities were 0.96, 0.90, and 0.85, and specificities were 0.82, 0.88, and 0.96, respectively. Exploratory subgroup analyses suggested performance variation across selected study and model characteristics, including region, algorithmic framework, data source, and validation method.
Conclusions
AI-based tools showed generally favorable screening performance for OSA across clinically relevant AHI thresholds, although wide PIs suggest variable performance across future comparable populations and settings. By synthesizing diagnostic accuracy across 3 AHI thresholds and distinguishing non-PSG–derived from PSG-derived models, this review extends previous broad or modality-specific reviews and offers a clinically interpretable, pathway-specific basis for linking model performance to intended use. The findings may clarify potential roles for non-PSG–derived tools in front-end screening and referral prioritization and for PSG-derived models in reduced-channel assessment and sleep-laboratory workflow support. Given substantial heterogeneity, limited external validation, and low or very low certainty of evidence, prospective validation is needed before routine implementation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Epidemiology and Health Statistics, School of Public Health, Tianjin Medical University, 22 Qixiangtai Road, Heping District, Tianjin, 300070, China, 86 022-83336619.
- Tianjin Key Laboratory of Environment, Nutrition and Public Health, Tianjin Medical University, Tianjin, China.
- Laboratory for Artificial Intelligence and Active Health, Tianjin Medical University, Tianjin, China.
- Jinqiu Hospital of Liaoning Province, Shenyang, China.
Zitieren
APA
Lv, Y., Zhou, L., Jiao, S., Lin, J., Sun, B., Hao, H., Jia, C., Wang, Y., Bu, L., & Lu, W. (2026). Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis. Journal of Medical Internet Research, 28, e92399-e92399. https://doi.org/10.2196/92399
Vancouver
Lv Y, Zhou L, Jiao S, Lin J, Sun B, Hao H, et al. Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis. Journal of Medical Internet Research. 2026;28:e92399-e92399. doi:10.2196/92399
BibTeX
@article{Lv2026,
author = {Lv, Yujia and Zhou, Lihui and Jiao, Sihan and Lin, Jiaying and Sun, Boran and Hao, Haixia and Jia, Chenxiao and Wang, Yuan and Bu, Li and Lu, Wenli},
title = {Performance of AI-Based Screening Tools for Obstructive Sleep Apnea Across Apnea-Hypopnea Index Thresholds: Systematic Review and Meta-Analysis},
journal = {Journal of Medical Internet Research},
year = {2026},
volume = {28},
pages = {e92399--e92399},
doi = {10.2196/92399}
}