Diagnostic Evaluation of Automatic Noncontact Ultra‐Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China
Canadian Respiratory Journal · 2025
DOI: 10.1155/carj/6631384 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Respiratory Journal, 2025. Verfasst von Shuyue Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Guangzhou Red Cross Hospital (Guangzhou Red Cross Hospital of Jinan University), Guangzhou 5…. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Oximetry, Radar. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangzhou Science and Technology Program key projects, Basic and Applied Basic Research Foundation of Guangdong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Polysomnography (PSG) is the traditional technique for diagnosing obstructive sleep apnea (OSA) with some limitations. Ultra‐wideband radar (UWB) is a new method for diagnosing OSA that combines multiple techniques including radar technology, artificial intelligence (AI), and big data algorithms. The accuracy of UWB in OSA diagnosis needs further scientific verification, especially in southern China.
Methods
Fifty patients from southern China wore UWB with oximetry and PSG simultaneously overnight. UWB generated automated reports; PSG was manually interpreted. Lowest oxygen saturation (LSpO2) and apnea‐hypopnea index (AHI) from both methods were compared.
Results
High correlation was found between UWB and PSG for AHI ( r = 0.925, p < 0.001) and LSpO2 ( r = 0.990, p < 0.001). The average bias of AHI (−3.09, p = 0.98, 95% CI −15.48 − 9.31) and LSpO2 (−0.34, p > 0.99, 95% CI −3.68 − 3.04) between the two methods was small. ROC analysis showed good diagnostic performance of UWB versus PSG (AUC = 0.979, p < 0.001), with 95.8% sensitivity and 100% specificity.
Conclusion
The study demonstrated UWB combined with oximetry could be a reliable alternative to PSG for diagnosing OSA in the south of China.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology-Head and Neck Surgery, Guangzhou Red Cross Hospital (Guangzhou Red Cross Hospital of Jinan University), Guangzhou 510220, China.
- Department of Otolaryngology Head and Neck Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510405, China.
- Institute of Otolaryngology Head and Neck Surgery, Jinan University, Guangzhou 510220, China.
- Lingnan Institute of Otolaryngology, Guangdong Clinical Research Academy of Chinese Medicine, Guangzhou 510405, China.
ORCID-Profile: Shuyue Wang, Jian Wu, Haiyao Zheng, Yan Ruan, Feng Yu, Tao Liao
Förderung
- Guangzhou Science and Technology Program key projects
- Basic and Applied Basic Research Foundation of Guangdong Province
- National Natural Science Foundation of China
Zitieren
APA
Wang, S., Wu, J., Zheng, H., Ruan, Y., Yu, F., & Liao, T. (2025). Diagnostic Evaluation of Automatic Noncontact Ultra‐Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China. Canadian Respiratory Journal. https://doi.org/10.1155/carj/6631384
Vancouver
Wang S, Wu J, Zheng H, Ruan Y, Yu F, Liao T. Diagnostic Evaluation of Automatic Noncontact Ultra‐Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China. Canadian Respiratory Journal. 2025. doi:10.1155/carj/6631384
BibTeX
@article{Wang2025,
author = {Wang, Shuyue and Wu, Jian and Zheng, Haiyao and Ruan, Yan and Yu, Feng and Liao, Tao},
title = {Diagnostic Evaluation of Automatic Noncontact Ultra‐Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China},
journal = {Canadian Respiratory Journal},
year = {2025},
doi = {10.1155/carj/6631384}
}