Evaluation of a Consumer Wearable Smartwatch for Cardiac Interval Measurement in Healthy Adults: Cross-Sectional Method Comparison Study
JMIR Formative Research · 04.09.2026 · 10 · e90009-e90009
DOI: 10.2196/90009 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift JMIR Formative Research, online erschienen am 04.09.2026. Verfasst von Nicholas Noggle und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of California San Diego, La Jolla, CA, United States. Hauptthemen laut MEDLINE: Electrocardiography, Wearable Electronic Devices, Heart Rate. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Commercially available wearable devices, capable of measuring cardiac rhythm, are gaining popularity for convenient heart health monitoring. Accurate measurement of key intervals, specifically RR intervals for rhythm and QT and corrected QT (QTc) intervals for arrhythmia risk, is crucial for assessing potential cardiac morbidity.
Objective
This study aimed to evaluate the agreement of RR, QT, and QTc intervals measured by a consumer wearable device (Withings ScanWatch series 1) with those measured using a research-grade 3-lead electrocardiogram (ECG; Biopac) and a clinically approved single-lead patch (Cardea SOLO).
Methods
This was a cross-sectional study of 28 healthy adults aged 21 to 65 years, with a mean age of 39.4 (SD 13.0) years. Participants underwent 4 concurrent ECG measurements per device: twice seated at rest, once supine, and once after exercise. All RR and QT intervals were manually measured using standardized caliper software (EP calipers) by trained reviewers, and QTc was calculated using the Bazett formula. Agreement was assessed via repeated-measures correlation ( r rm ) and linear mixed-effects models (LMMs) for repeated-measures Bland-Altman analysis.
Results
Strong agreement was observed for RR intervals when comparing the Withings ScanWatch with both the Biopac ( r rm =0.84; P< .001) and the SOLO ( r rm =0.80; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, University of California San Diego, La Jolla, CA, United States.
- School of Medicine, Albany Medical College, Albany, NY, United States.
- Herbert Wertheim School of Public Health and Human Longevity, University of California San Diego, La Jolla, CA, United States.
- Exercise and Physical Activity Resource Center, University of California San Diego, 9500 Gilman Drive, dept #0811, La Jolla, CA, 92093, United States, 1 (858) 534-9315.
- School of Medicine, University of Hawaii Cancer Center, Honolulu, HI, United States.
- Digital Health Sciences, Takeda (United States), Cambridge, MA, United States.
ORCID-Profile: Nicholas Noggle, David Wing, Job Godino, Michael Higgins, Daniel Moreno, Dylan Lawton, Ariel Dowling, Jasmin Imsirovic, Ryan Moran
Zitieren
APA
Noggle, N., Wing, D., Godino, J., Higgins, M., Moreno, D., Lawton, D., Dowling, A., Imsirovic, J., & Moran, R. (2026). Evaluation of a Consumer Wearable Smartwatch for Cardiac Interval Measurement in Healthy Adults: Cross-Sectional Method Comparison Study. JMIR Formative Research, 10, e90009-e90009. https://doi.org/10.2196/90009
Vancouver
Noggle N, Wing D, Godino J, Higgins M, Moreno D, Lawton D, et al. Evaluation of a Consumer Wearable Smartwatch for Cardiac Interval Measurement in Healthy Adults: Cross-Sectional Method Comparison Study. JMIR Formative Research. 2026;10:e90009-e90009. doi:10.2196/90009
BibTeX
@article{Noggle2026,
author = {Noggle, Nicholas and Wing, David and Godino, Job and Higgins, Michael and Moreno, Daniel and Lawton, Dylan and Dowling, Ariel and Imsirovic, Jasmin and Moran, Ryan},
title = {Evaluation of a Consumer Wearable Smartwatch for Cardiac Interval Measurement in Healthy Adults: Cross-Sectional Method Comparison Study},
journal = {JMIR Formative Research},
year = {2026},
volume = {10},
pages = {e90009--e90009},
doi = {10.2196/90009}
}
EUVIMED