Using a wearable-based animated patient avatar to improve patients’ perception of vital signs: A multicenter computer-based study (Preprint)

Johannes Köhler iD, Max Ebensperger iD, Cynthia A Hunn iD, Arend Rahrisch iD, Achilles Delis iD, Florian Piekarski iD, Gregor Massoth iD, Florian J Raimann iD, Kai Zacharowski iD, David W Tscholl iD, Tadzio Raoul Roche iD

JMIR Formative Research · 2025

DOI: 10.2196/84130 ↗

At a glance

Multizentrische Studie in JMIR Formative Research, 2025. Written by Johannes Köhler and 10 co-authors. Institution: Institute for Anesthesiology and Perioperative Medicine, University and University Hospital Zurich, Zurich, Switzerland. Major MEDLINE topics: Avatar, Vital Signs, Wearable Electronic Devices, Perception. 37 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

BACKGROUND: Visual patient avatars are an innovative patient monitoring technology that can be used to translate numerical and waveform data into intuitive, avatar-based representations of patient conditions. Previous research indicates that this technology improves health care providers' situational awareness compared to conventional monitoring methods. As patient-worn continuous vital sign monitoring continues to evolve, we introduce the Visual Patient Wearable device to provide avatar-based visualization tailored to this application. OBJECTIVE: This study aimed to evaluate whether a wearable-based animated patient avatar can improve patients' perception and recall of simulated vital sign deviations compared to conventional monitoring methods, and to assess the usability and acceptance of this avatar-based visualization. METHODS: This computer-based study included 67 patients from 3 academic hospitals in Central Europe. Participants were randomly assigned to a Visual Patient Wearable group or a conventional monitoring group and viewed a standardized instructional video for their allocated method. They then completed 4 randomized clinical scenarios, each displayed for 6 seconds to simulate glance-based assessment. Accuracy in recalling vital sign deviations was measured, and Visual Patient Wearable participants additionally gave user feedback on Likert scales. RESULTS: The Visual Patient Wearable system was associated with higher detection accuracy of vital sign deviations compared with standard monitoring layouts, increasing from a median correctness of 46% (IQR 33%-63%) with conventional monitoring to a median of 67% (IQR 49%-79%) with the Visual Patient Wearable system (P

Subjects

MeSH terms (MEDLINE)

AvatarVital SignsWearable Electronic DevicesPerceptionHumansFemaleMaleMiddle AgedAdultAgedMonitoring, Physiologic

Author keywords

diagnosispatient avatarspatient monitoringsituation awarenessusabilityvital sign informationwearable

Authors and institutions

  • Institute for Anesthesiology and Perioperative Medicine, University and University Hospital Zurich, Zurich, Switzerland.
  • Department of Anesthesiology and Intensive Care, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
  • Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany.
  • Goethe University Frankfurt, University Hospital, Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Frankfurt, Germany.

ORCID profiles: Johannes Köhler, Max Ebensperger, Cynthia A Hunn, Arend Rahrisch, Achilles Delis, Florian Piekarski, Gregor Massoth, Florian J Raimann, Kai Zacharowski, David W Tscholl, Tadzio Raoul Roche

Cite

APA

Köhler, J., Ebensperger, M., Hunn, C. A., Rahrisch, A., Delis, A., Piekarski, F., Massoth, G., Raimann, F. J., Zacharowski, K., Tscholl, D. W., & Roche, T. R. (2025). Using a wearable-based animated patient avatar to improve patients’ perception of vital signs: A multicenter computer-based study (Preprint). JMIR Formative Research. https://doi.org/10.2196/84130

Vancouver

Köhler J, Ebensperger M, Hunn CA, Rahrisch A, Delis A, Piekarski F, et al. Using a wearable-based animated patient avatar to improve patients’ perception of vital signs: A multicenter computer-based study (Preprint). JMIR Formative Research. 2025. doi:10.2196/84130

BibTeX
@article{Khler2025,
  author = {Köhler, Johannes and Ebensperger, Max and Hunn, Cynthia A and Rahrisch, Arend and Delis, Achilles and Piekarski, Florian and Massoth, Gregor and Raimann, Florian J and Zacharowski, Kai and Tscholl, David W and Roche, Tadzio Raoul},
  title = {Using a wearable-based animated patient avatar to improve patients’ perception of vital signs: A multicenter computer-based study (Preprint)},
  journal = {JMIR Formative Research},
  year = {2025},
  doi = {10.2196/84130}
}
Start for free →