Feasibility of a Noncontact Photoplethysmography–Based Mobile App for Noninvasive Hemoglobin Monitoring: Exploratory Observational Study
JMIR Formative Research · 2026
DOI: 10.2196/78820 ↗At a glance
Beobachtungsstudie in JMIR Formative Research, 2026. Written by Gianvincenzo Zuccotti and 16 co-authors. Institution: Department of Biomedical and Clinical Science, University of Milan, Via GB Battista 32, Milan, 20154, Italy, 39 0263635321. Major MEDLINE topics: Photoplethysmography, Mobile Applications, Hemoglobins. 61 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
Anemia is a widespread global health issue. Hemoglobin (Hb) concentration measurement remains the most common method for anemia screening and diagnosis. In recent years, there has been growing interest in the development of noninvasive point-of-care technologies that eliminate the need for blood sampling.
Objective
This pilot study explores the feasibility of using a noncontact photoplethysmography–based mobile app for Hb monitoring.
Methods
Adult volunteers aged 18 years and older, of both sexes, were consecutively recruited. Participants were seated and allowed a 2-minute rest before measurements. During testing, they faced a smartphone running comestai.app , which used the front-facing camera to capture facial videos. Simultaneous readings were collected for Hb over approximately 90 seconds using the app. Ambient lighting was standardized for all remote photoplethysmography recordings. No medical decisions were made based on the app-generated data. A complete blood count, including Hb levels, was used as a reference for comparison with the data collected using comestai.app.
Results
A total of 555 (female: n=313, 56.4%; male: n=242, 43.6%) individuals participated in the study. The app achieved a mean absolute error of 1.46, a mean absolute percentage error of 11.26, a mean error of −0.67, and a root mean square error of 1.88. The Bland-Altman plot evaluated the agreement between the app-based and laboratory-based Hb measurements, with the mean difference between the 2 methods being −0.70 g/dL. The method demonstrated an overall accuracy of 75%. The area under the curve was 0.701 (95% CI 0.655-0.745).
Conclusions
Comestai.app offers an innovative approach to wellness monitoring by providing noninvasive Hb estimation using the smartphone’s front-facing camera. Continued development, including algorithmic refinement and larger-scale validation in diverse populations, will be key to enhancing accuracy and broadening its utility. By leveraging the ubiquity of smartphones, comestai.app contributes meaningfully to the democratization of health monitoring and the promotion of proactive self-care.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Biomedical and Clinical Science, University of Milan, Via GB Battista 32, Milan, 20154, Italy, 39 0263635321.
- Pediatric Department, Buzzi Children's Hospital, Milan, Italy.
- Come Stai S.p.A., Milan, Italy.
- Department of Internal Medicine, Pediatric and Adolescent Unit, University of Pavia, Pavia, Italy.
- Division of Endocrinology, ASST Fatebenefratelli-Sacco, Milan, Italy.
- Department of Biomedical and Clinical Science, International Center for T1D, Pediatric Clinical Research Center Romeo ed Enrica Invernizzi, University of Milano, Milan, Italy.
ORCID profiles: Gianvincenzo Zuccotti, Paolo Agnelli, Lucia Labati, Erika Cordaro, Davide Braghieri, Paolo Fiorina, Simona Bertoli, Cesare Celeste Federico Berra, Marina Croci, Maria Elena Malighetti, Fabrizio Losurdo, Andrea Foppiani, Loredana Bucciarelli, Marco Xodo, Alberto Battezzati, Sergio De Pasquale, Valeria Calcaterra
Cite
APA
Zuccotti, G., Agnelli, P., Labati, L., Cordaro, E., Braghieri, D., Fiorina, P., Bertoli, S., Berra, C. C. F., Croci, M., Malighetti, M. E., Losurdo, F., Foppiani, A., Bucciarelli, L., Xodo, M., Battezzati, A., De Pasquale, S., & Calcaterra, V. (2026). Feasibility of a Noncontact Photoplethysmography–Based Mobile App for Noninvasive Hemoglobin Monitoring: Exploratory Observational Study. JMIR Formative Research. https://doi.org/10.2196/78820
Vancouver
Zuccotti G, Agnelli P, Labati L, Cordaro E, Braghieri D, Fiorina P, et al. Feasibility of a Noncontact Photoplethysmography–Based Mobile App for Noninvasive Hemoglobin Monitoring: Exploratory Observational Study. JMIR Formative Research. 2026. doi:10.2196/78820
BibTeX
@article{Zuccotti2026,
author = {Zuccotti, Gianvincenzo and Agnelli, Paolo and Labati, Lucia and Cordaro, Erika and Braghieri, Davide and Fiorina, Paolo and Bertoli, Simona and Berra, Cesare Celeste Federico and Croci, Marina and Malighetti, Maria Elena and Losurdo, Fabrizio and Foppiani, Andrea and Bucciarelli, Loredana and Xodo, Marco and Battezzati, Alberto and De Pasquale, Sergio and Calcaterra, Valeria},