EUVIMEDDescoperă EUVIMED
Open access

Enhancing Anesthetic Depth Assessment via Unsupervised Machine Learning in Processed Electroencephalography Analysis: Novel Methodological Study

Po-Yu Huang iD, Wei-Lun Hong iD, Hui-Zen Hee iD, Wen-Kuei Chang iD, Ching-Hung Lee iD, Chien-Kun Ting iD

JMIR Medical Informatics · 2026

DOI: 10.2196/77830 ↗

At a glance

Journal article in JMIR Medical Informatics, 2026. Written by Po-Yu Huang and 5 co-authors. Institution: Department of Anesthesiology, Taipei Veterans General Hospital, No. 201, Sec 2, Shipai Rd, Beitou District, Taipei City, 11217, Taiwan, 886 228757549. Major MEDLINE topics: Electroencephalography, Unsupervised Machine Learning, Anesthesia, General. 46 references. The full text is freely available in PubMed Central.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Background

General anesthesia comprises 3 essential components—hypnosis, analgesia, and immobility. Among these, maintaining an appropriate hypnotic state, or anesthetic depth, is crucial for patient safety. Excessively deep anesthesia may lead to hemodynamic instability and postoperative cognitive dysfunction, whereas inadequate anesthesia increases the risk of intraoperative awareness. Electroencephalography (EEG)-based monitoring has therefore become a cornerstone for evaluating anesthetic depth. However, processed electroencephalography (pEEG) indices remain vulnerable to various sources of interference, including electromyographic activity, interindividual variability, and anesthetic drug effects, which can yield inaccurate numerical outputs.

Objective

With recent advances in machine learning, particularly unsupervised learning, data-driven methods that classify signals according to inherent patterns offer new possibilities for anesthetic depth analysis. This study aimed to establish a methodology for automatically identifying anesthesia depth using an unsupervised, machine learning–based clustering approach applied to pEEG data.

Methods

Standard frontal EEG data from participants undergoing elective lumbar spine surgery were retrospectively analyzed, yielding more than 16,000 data points. The signals were filtered with a fourth-order Butterworth bandpass filter and transformed using the fast Fourier transform to estimate power spectral density. Normalized band power ratios for delta, high-theta, alpha, and beta frequencies were extracted as input features. Fuzzy C-Means (FCM) clustering ( c =3, m =2) was applied to categorize anesthetic depth into slight, proper, and deep clusters.

Results

FCM clustering successfully identified 3 physiologically interpretable clusters consistent with EEG dynamics during progressive anesthesia. As anesthesia deepened, frontal alpha oscillations became more prominent within a delta-dominant background, while beta activity decreased with loss of consciousness. The fuzzy membership values quantified transitional states and captured the continuum of anesthetic depth. Visualization confirmed strong correspondence among cluster transitions, Patient State Index trends, and spectral density patterns.

Conclusions

This study demonstrates the feasibility of using unsupervised machine learning to enhance anesthetic depth assessment. By applying FCM clustering to pEEG data, this approach improves the understanding of anesthesia depth and integrates effectively with existing monitoring modalities. The proposed FCM-based method complements current EEG indices and may assist anesthesia practitioners and even nonanesthesia professionals in assessing anesthetic depth to enhance patient safety.

Subjects

MeSH terms (MEDLINE)

ElectroencephalographyUnsupervised Machine LearningAnesthesia, GeneralHumansRetrospective StudiesClustering AlgorithmsCluster Analysis

Author keywords

artificial intelligencecluster analysiselectroencephalographygeneral anesthesiaintraoperative monitoringmachine learning

Authors and institutions

  • Department of Anesthesiology, Taipei Veterans General Hospital, No. 201, Sec 2, Shipai Rd, Beitou District, Taipei City, 11217, Taiwan, 886 228757549.
  • Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu City, Taiwan.
  • Department of Anesthesiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
  • Department of Electrical Engineering, Chung Yuan Christian University, Taoyuan City, Taiwan.
  • Institute of Emergency and Critical Care Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan.

ORCID profiles: Po-Yu Huang, Wei-Lun Hong, Hui-Zen Hee, Wen-Kuei Chang, Ching-Hung Lee, Chien-Kun Ting

Cite

APA

Huang, P. Y., Hong, W. L., Hee, H. Z., Chang, W. K., Lee, C. H., & Ting, C. K. (2026). Enhancing Anesthetic Depth Assessment via Unsupervised Machine Learning in Processed Electroencephalography Analysis: Novel Methodological Study. JMIR Medical Informatics. https://doi.org/10.2196/77830

Vancouver

Huang PY, Hong WL, Hee HZ, Chang WK, Lee CH, Ting CK. Enhancing Anesthetic Depth Assessment via Unsupervised Machine Learning in Processed Electroencephalography Analysis: Novel Methodological Study. JMIR Medical Informatics. 2026. doi:10.2196/77830

BibTeX
@article{Huang2026,
  author = {Huang, Po-Yu and Hong, Wei-Lun and Hee, Hui-Zen and Chang, Wen-Kuei and Lee, Ching-Hung and Ting, Chien-Kun},
  title = {Enhancing Anesthetic Depth Assessment via Unsupervised Machine Learning in Processed Electroencephalography Analysis: Novel Methodological Study},
  journal = {JMIR Medical Informatics},
  year = {2026},
  doi = {10.2196/77830}
}
Start for free →