Diagnostic Performance of Deep Learning and Radiomics in Extracranial Carotid Plaque Detection: Systematic Review and Meta-Analysis
Journal of Medical Internet Research · 2026-01-22 · 28 · e77092-e77092
DOI: 10.2196/77092 ↗At a glance
Systematische Übersicht in Journal of Medical Internet Research, published online on 2026-01-22. Written by Lingjie Ju and 7 co-authors. Institution: Department of Sonography, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences & Pe…. Major MEDLINE topics: Deep Learning, Carotid Stenosis, Plaque, Atherosclerotic. Cited 4 times so far (Crossref); 87 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
Artificial intelligence–enhanced imaging techniques have demonstrated promising diagnostic potential for carotid plaques, a key cardiovascular and cerebrovascular risk factor. However, previous studies did not systematically synthesize their diagnostic accuracy.
Objective
This study aimed to quantitatively explore the diagnostic efficacy of deep learning (DL) and radiomics for extracranial carotid plaques and establish a standardized framework for improving plaque detection.
Methods
We searched the PubMed, Embase, Cochrane, Web of Science, and Institute of Electrical and Electronics Engineers databases to identify studies involving the use of radiomics or DL models to diagnose extracranial carotid artery plaques from inception up to September 24, 2025. The quality of the studies was determined using Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence (QUADAS-AI). A meta-analysis was conducted using StataMP (version 17.0; StataCorp) with a bivariate mixed-effects model to calculate pooled sensitivity and specificity, generate summary receiver operating characteristic (SROC) curves, assess Cochran Q statistic and I ²-based heterogeneity, and conduct subgroup analyses and regression analysis.
Results
Among 40 studies comprising 17,246 patients, 34 integrated independent test sets or validation sets in the quantitative statistical analysis. Among them, 24 focused on DL models, 10 on machine learning models based on radiomics. The combined sensitivity, specificity, and area under the SROC curve were 0.88 (95% CI 0.85‐0.91; P
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Sonography, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, 1 Dahua Road, Dongdan, Dongcheng District,…
- Department of Sonography, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Peking University Health Science Center, Beijing, China.
- Department of Sonography, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China.
Cite
APA
Ju, L., Guo, Y., Guo, H., Liu, R., Wang, Y., Wang, S., Ma, N., & Ren, J. (2026). Diagnostic Performance of Deep Learning and Radiomics in Extracranial Carotid Plaque Detection: Systematic Review and Meta-Analysis. Journal of Medical Internet Research, 28, e77092-e77092. https://doi.org/10.2196/77092
Vancouver
Ju L, Guo Y, Guo H, Liu R, Wang Y, Wang S, et al. Diagnostic Performance of Deep Learning and Radiomics in Extracranial Carotid Plaque Detection: Systematic Review and Meta-Analysis. Journal of Medical Internet Research. 2026;28:e77092-e77092. doi:10.2196/77092
BibTeX
@article{Ju2026,
author = {Ju, Lingjie and Guo, Yongsheng and Guo, Haiyong and Liu, Ruijuan and Wang, Yiyang and Wang, Siyu and Ma, Na and Ren, Junhong},
title = {Diagnostic Performance of Deep Learning and Radiomics in Extracranial Carotid Plaque Detection: Systematic Review and Meta-Analysis},
journal = {Journal of Medical Internet Research},
year = {2026},
volume = {28},
pages = {e77092--e77092},
doi = {10.2196/77092}
}
EUVIMED