EUVIMEDAtrasti EUVIMED
Scoping ReviewOpen access

Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature

Clarissa Pedrini Schuch, Gabriela Chaves, Bastien Moineau, Sarah Bennett, Meysam Pirbaglou, Edwin Martin Lobo, Milad Alizadeh-Meghrazi

JMIR Cardio · 2026-03-02 · 10 · e74261-e74261

DOI: 10.2196/74261 ↗

At a glance

Scoping Review in JMIR Cardio, published online on 2026-03-02. Written by Clarissa Pedrini Schuch and 6 co-authors. Institution: Research and Development, Myant Health Corp, 2660 Speakman Dr, Mississauga, ON, L5K 2L1, Canada, 1 4379993141. Major MEDLINE topics: Textiles, Electrocardiography, Ambulatory, Wearable Electronic Devices. Cited 3 times so far (Crossref); 98 references. The full text is freely available in PubMed Central.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Background

Smart textiles (ie, electronic textiles) offer a promising solution to ease continuous electrocardiogram (ECG) monitoring, but their real-world clinical application has been limited.

Objective

This review comprehensively examines the current state of research on textile-based ECG monitoring systems, synthesizing current evidence with respect to performance (ie, signal quality, function under static and dynamic conditions), user experience, and current challenges.

Methods

A systematic literature search across the PubMed, MEDLINE, and Embase databases from 2000 to 2025 identified 34 research papers eligible for inclusion.

Results

Textile-based ECG electrodes demonstrated good signal quality and comfort, particularly under static conditions. Nonetheless, integration into clinical practice requires addressing critical issues, which include greater efforts at validating these technologies in clinical settings and populations, as well as ensuring data security, cost‑effectiveness, user‑friendliness, and data interoperability.

Conclusions

Considering the prominence of feasibility research, the successful clinical integration of textile-based ECG monitoring systems requires comprehensive efforts at establishing a clinical evaluation research base (via clinical trials) and developing regulatory policies.

Subjects

MeSH terms (MEDLINE)

TextilesElectrocardiography, AmbulatoryWearable Electronic DevicesHumansDigital Health

Author keywords

ECGPRISMAPreferred Reporting Items for Systematic Reviews and Meta-Analysescardiac monitoringelectrocardiogramremote patient monitoringsmart textileswearable

Authors and institutions

  • Research and Development, Myant Health Corp, 2660 Speakman Dr, Mississauga, ON, L5K 2L1, Canada, 1 4379993141.
  • Institute of Health Policy, Management and Evaluation, Dalla Lana School of Public Health, University of Toronto, Toronto, ON, Canada.
  • Software Quality Assurance, Myant Health Corp, Mississauga, ON, Canada.

Cite

APA

Pedrini Schuch, C., Chaves, G., Moineau, B., Bennett, S., Pirbaglou, M., Lobo, E. M., & Alizadeh-Meghrazi, M. (2026). Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature. JMIR Cardio, 10, e74261-e74261. https://doi.org/10.2196/74261

Vancouver

Pedrini Schuch C, Chaves G, Moineau B, Bennett S, Pirbaglou M, Lobo EM, et al. Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature. JMIR Cardio. 2026;10:e74261-e74261. doi:10.2196/74261

BibTeX
@article{PedriniSchuch2026,
  author = {Pedrini Schuch, Clarissa and Chaves, Gabriela and Moineau, Bastien and Bennett, Sarah and Pirbaglou, Meysam and Lobo, Edwin Martin and Alizadeh-Meghrazi, Milad},
  title = {Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature},
  journal = {JMIR Cardio},
  year = {2026},
  volume = {10},
  pages = {e74261--e74261},
  doi = {10.2196/74261}
}
Start for free →