Validierungsstudie in JMIR Formative Research, published online on 2025-09-30. Written by Hidde J Hardon and 4 co-authors. Institution: Division of Pediatric Cardiology, Department of Pediatrics, Erasmus MC, Dr Molewaterplein 40, Rotterdam, 3015GD, The Netherlands, 31 10 704 0704. Major MEDLINE topics: Heart Rate, Electrocardiography, Ambulatory, Wearable Electronic Devices, Heart Diseases. Cited 8 times so far (Crossref); 46 references. The full text is freely available in PubMed Central.
Topics: Kinderkrankenpflege
Abstract (original language)
Background
Wearables are increasingly used in pediatric cardiology for heart rate (HR) monitoring due to advantages over traditional HR monitoring, such as prolonged monitoring time, increased patient comfort, and ease of use. However, their validation in this population is limited.
Objective
The objective of this paper was to assess HR accuracy and validity from 2 wearables, the Corsano CardioWatch bracelet and the Hexoskin smart shirt, in children attending the pediatric cardiology outpatient clinic, exploring factors that influence accuracy, the Hexoskin shirt’s arrhythmia detection efficacy, and patient satisfaction.
Methods
Children with an indication for 24-hour Holter monitoring were equipped with a 24-hour Holter electrocardiogram (ECG; gold standard), together with both wearables. HR accuracy was defined as the percentage of HRs within 10% of Holter values, and agreement was assessed using Bland-Altman analysis. Subgroup analyses were conducted based on BMI, age, and time of wearing, among other factors. The association between accelerometry (expressed in gravitational units, g) and HR accuracy was analyzed to assess the impact of bodily movement on measurement accuracy. A blinded pediatric cardiologist analyzed Hexoskin shirt data for rhythm classification. Patient satisfaction was measured using a 5-point Likert scale questionnaire.
Results
A total of 31 participants (mean age 13.2, SD 3.6 y; n=14, 45% female) and 36 participants (mean age 13.3, SD 3.9 y) were included for the CardioWatch and Hexoskin measurements, respectively. Mean accuracy was 84.8% (SD 8.7%) for the CardioWatch and 87.4% (SD 11%) for the Hexoskin shirt. Hexoskin shirt accuracy was notably higher in the first 12 hours (94.9%, SD 7.4%) compared to the latter 12 (80%, SD 16.7%; P
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Pediatric Cardiology, Department of Pediatrics, Erasmus MC, Dr Molewaterplein 40, Rotterdam, 3015GD, The Netherlands, 31 10 704 0704.
ORCID profiles: Hidde J Hardon, Yara N Van Kerkhof, Beatrijs Bartelds, Janneke A E Kammeraad, Arend W Van Deutekom
Cite
APA
Hardon, H. J., Van Kerkhof, Y. N., Bartelds, B., Kammeraad, J. A. E., & Van Deutekom, A. W. (2025). The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study. JMIR Formative Research, 9, e70835-e70835. https://doi.org/10.2196/70835
Vancouver
Hardon HJ, Van Kerkhof YN, Bartelds B, Kammeraad JAE, Van Deutekom AW. The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study. JMIR Formative Research. 2025;9:e70835-e70835. doi:10.2196/70835
BibTeX
@article{Hardon2025,
author = {Hardon, Hidde J and Van Kerkhof, Yara N and Bartelds, Beatrijs and Kammeraad, Janneke A E and Van Deutekom, Arend W},
title = {The Validation and Accuracy of Wearable Heart Rate Trackers in Children With Heart Disease: Prospective Cohort Study},
journal = {JMIR Formative Research},
year = {2025},
volume = {9},
pages = {e70835--e70835},
doi = {10.2196/70835}
}
EUVIMED