EUVIMEDΑνακαλύψτε το EUVIMED
VergleichsstudieValidierungsstudieStudienprotokollOpen access

Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study

Roberto M Benzo iD, Rujul Singh iD, Carolyn J Presley iD, Macy K Tetrick iD, Zachary L Chaplow iD, Chloe M Hery iD, Jane Yu iD, Peter Washington iD, Frank J Penedo iD, Electra D Paskett iD, Vipul Lugade iD, Emma Fortune iD

JMIR Research Protocols · 2025

DOI: 10.2196/70472 ↗

At a glance

Vergleichsstudie in JMIR Research Protocols, 2025. Written by Roberto M Benzo and 11 co-authors. Institution: Division of Cancer Prevention and Control, Department of Internal Medicine, The Ohio State Comprehensive Cancer Center, College of Medicine, The Ohio…. Major MEDLINE topics: Lung Neoplasms, Wearable Electronic Devices, Exercise, Fitness Trackers. Cited 3 times so far (Crossref); 69 references. The full text is freely available in PubMed Central.

ΠερίληψηSubjectsΒιβλιογραφικά στοιχείαCiteRelated studies

Abstract (original language)

Background

Wearable activity monitors (WAMs) provide insights into physical activity (PA) and are widely used in behavioral interventions and cancer survivorship research. However, validation studies of wearable devices in populations with cancer are scarce, and existing studies using activity monitors in patients with cancer lack standardization. This gap is particularly significant in patients with lung cancer (LC), who often experience unique mobility challenges and gait impairments that may affect device accuracy. This study addresses this gap by validating the Fitbit Charge 6, ActiGraph LEAP, and activPAL3 micro in patients with LC in both laboratory and free-living conditions and developing a standardized framework for assessing wearable devices in populations with cancer and impaired mobility.

Objective

This study aims to validate and compare the accuracy of consumer-grade (Fitbit Charge 6) and research-grade (activPAL3 micro and ActiGraph LEAP) WAMs in patients with LC under both laboratory and free-living conditions. Moreover, this protocol aims to establish standardized procedures that can be adapted for validating current and future generations of wearable devices while accounting for disease-specific factors that may impact measurement accuracy.

Methods

In total, 15 adults diagnosed with LC (stages 1-4) will participate in laboratory and free-living protocols, wearing Fitbit Charge 6, activPAL3 micro, and ActiGraph LEAP devices simultaneously. The laboratory protocol will consist of a series of structured activities, including variable-time walking trials, sitting and standing tests, posture changes, and gait speed assessments. Activities will be video recorded for validation. In the free-living protocol, participants will wear the devices continuously for 7 days except during water-based activities. WAM-based outcome measures will include step count; time spent at light, moderate, and vigorous PA intensity levels; posture; and posture changes (only the activPAL3 micro measured posture). Validated survey instruments will be administered both before and after WAM data collection to control for potential confounding factors that may influence movement patterns and device accuracy. Laboratory-based validity measures will compare WAM data to video-recorded observations. Sensitivity, specificity, positive predictive value, and agreement will also be determined. Free-living agreement between devices will be assessed using Bland-Altman plots, intraclass correlation analysis, and 95% limits of agreement.

Results

Data collection is ongoing, with 11 participants enrolled and 7 (64%) having completed both in-laboratory and free-living protocols. On average, enrolled participants are aged 63.0 (SD 7.8; range 50.0-73.0) years, with 8 (73%) participants being women. Participant enrollment is expected to conclude in mid-2025, and initial findings are expected to be disseminated by the end of 2025.

Conclusions

This is the first study that validates WAM accuracy for populations with LC while providing comprehensive recommendations for future validation studies. This study will provide critical insights into the accuracy and reliability of WAMs for assessing PA in LC survivors, which are essential for interpreting clinical research and informing future interventions. International Registered Report Identifier (IRRID) DERR1-10.2196/70472

Subjects

MeSH terms (MEDLINE)

Lung NeoplasmsWearable Electronic DevicesExerciseFitness TrackersHumansPilot ProjectsMaleFemaleReproducibility of ResultsMiddle AgedAdultAged

Author keywords

ActiGraphFitbitactivPAL3 microcancer survivorshipconsumer technologydigital healthlung cancerphysical activity monitoringvalidation studywearable devices

Authors and institutions

  • Division of Cancer Prevention and Control, Department of Internal Medicine, The Ohio State Comprehensive Cancer Center, College of Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, United States.
  • Division of Medical Oncology, Department of Internal Medicine, The Ohio State Comprehensive Cancer Center, College of Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, United States.
  • Kinesiology, Department of Human Sciences, The Ohio State University, Columbus, OH, United States.
  • College of Medicine, The Ohio State University, Columbus, OH, United States.
  • Division of Clinical Informatics and Digital Transformation, Department of Medicine, University of California - San Francisco, San Francisco, CA, United States.
  • Departments of Psychology and Medicine, University of Miami, Coral Gables, FL, United States.

ORCID profiles: Roberto M Benzo, Rujul Singh, Carolyn J Presley, Macy K Tetrick, Zachary L Chaplow, Chloe M Hery, Jane Yu, Peter Washington, Frank J Penedo, Electra D Paskett, Vipul Lugade, Emma Fortune

Cite

APA

Benzo, R. M., Singh, R., Presley, C. J., Tetrick, M. K., Chaplow, Z. L., Hery, C. M., Yu, J., Washington, P., Penedo, F. J., Paskett, E. D., Lugade, V., & Fortune, E. (2025). Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study. JMIR Research Protocols. https://doi.org/10.2196/70472

Vancouver

Benzo RM, Singh R, Presley CJ, Tetrick MK, Chaplow ZL, Hery CM, et al. Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study. JMIR Research Protocols. 2025. doi:10.2196/70472

BibTeX
@article{Benzo2025,
  author = {Benzo, Roberto M and Singh, Rujul and Presley, Carolyn J and Tetrick, Macy K and Chaplow, Zachary L and Hery, Chloe M and Yu, Jane and Washington, Peter and Penedo, Frank J and Paskett, Electra D and Lugade, Vipul and Fortune, Emma},
  title = {Comparing the Accuracy of Different Wearable Activity Monitors in Patients With Lung Cancer and Providing Initial Recommendations: Protocol for a Pilot Validation Study},
  journal = {JMIR Research Protocols},
  year = {2025},
  doi = {10.2196/70472}
}
Start for free →