Localized Muscular Fatigue in Robotic-Assisted Laparoscopic Surgery: Predictive Modeling Study
JMIR Formative Research · 2025
DOI: 10.2196/68536 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR Formative Research, 2025. Verfasst von Daniel Caballero und 3 weiteren Autor:innen. Beteiligte Einrichtung: Bioengineering and Health Technologies Unit, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Cáceres, Spain. Hauptthemen laut MEDLINE: Muscle Fatigue, Electromyography, Laparoscopy, Ergonomics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Robotic-assisted surgery (RAS) has grown rapidly in recent decades, and several RAS procedures have become the standard. However, the physical and mental demands of minimally invasive surgery (MIS) techniques can lead to ergonomic shortcomings for surgeons. Advances in wearable technology and artificial intelligence favor the development of innovative solutions to analyze and improve ergonomic conditions during surgical practice.
Objective
The main objective is the development and validation of a predictive model of localized muscle fatigue from electromyography (EMG) data during conventional laparoscopic surgery (LAP) and RAS.
Methods
Four different tasks were performed on LAP and RAS: dissection, labyrinth, peg transfer, and suturing. A wireless EMG sensor system was used to record muscle activity. Joint analysis of the spectrum and analysis graphs was used to evaluate the localized muscle fatigue. A dataset was generated for each task as a function of surgeons’ expertise level and surgical type. Each dataset was scaled as preprocessing and divided into 2 datasets: 80% for training and 20% for testing. Multiple linear regression (MLR) and multilayer perceptron (MLP) were applied as predictive techniques and validated on all test datasets. R2 coefficient and root-mean-square error were used to measure the accuracy of the models.
Results
RAS showed less muscle fatigue for novice surgeons compared to LAP practice, although it was higher for expert surgeons. The predictive model achieved satisfactory R2 and root-mean-square error coefficients for all parameters extracted from the EMG signal, predicting with high accuracy localized muscle fatigue values. The MLR predictive model demonstrated superior performance relative to the MLP model.
Conclusions
Wearable technology and artificial intelligence techniques have been successfully applied for the development and validation of a novel predictive model based on MLR and MLP to predict localized muscle fatigue in MIS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Bioengineering and Health Technologies Unit, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Cáceres, Spain.
- Scientific Direction, Jesús Usón Minimally Invasive Surgery Centre, Cáceres, Cáceres, Spain.
ORCID-Profile: Daniel Caballero, Manuel J Pérez-Salazar, Juan A Sánchez-Margallo, Francisco M Sánchez-Margallo
Zitieren
APA
Caballero, D., Pérez-Salazar, M. J., Sánchez-Margallo, J. A., & Sánchez-Margallo, F. M. (2025). Localized Muscular Fatigue in Robotic-Assisted Laparoscopic Surgery: Predictive Modeling Study. JMIR Formative Research. https://doi.org/10.2196/68536
Vancouver
Caballero D, Pérez-Salazar MJ, Sánchez-Margallo JA, Sánchez-Margallo FM. Localized Muscular Fatigue in Robotic-Assisted Laparoscopic Surgery: Predictive Modeling Study. JMIR Formative Research. 2025. doi:10.2196/68536
BibTeX
@article{Caballero2025,
author = {Caballero, Daniel and Pérez-Salazar, Manuel J and Sánchez-Margallo, Juan A and Sánchez-Margallo, Francisco M},
title = {Localized Muscular Fatigue in Robotic-Assisted Laparoscopic Surgery: Predictive Modeling Study},
journal = {JMIR Formative Research},
year = {2025},
doi = {10.2196/68536}
}
EUVIMED