Background
The insertable cardiac monitor (ICM) clinical pathway in Tampere Heart Hospital, Finland, did not correspond to the diagnostic needs of the population. There has been growing evidence of delegating the insertion from cardiologists to specially trained nurses and outsourcing the remote follow-up. However, it is unclear if the change in the clinical pathway is safe and improves efficiency.
Objective
We aim to describe and assess the efficiency of the change in the ICM clinical pathway.
Methods
Pathway improvements included initiating nurse-performed insertions, relocating the procedure from the catheterization laboratory to a procedure room, and outsourcing part of the remote follow-up to manage ICM workload. Data were collected from electronic health records of all patients who received an ICM in the Tampere Heart Hospital in 2018 and 2020. Follow-up time was 36 months after insertion.
Results
The number of inserted ICMs doubled from 74 in 2018 to 159 in 2020. In 2018, cardiologists completed all insertions, while in 2020, a total of 70.4% (n=112) were completed by nurses. The waiting time from referral to procedure was significantly shorter in 2020 (mean 36, SD 27.7 days) compared with 2018 (mean 49, SD 37.3 days; P =.02). The scheduled ICM procedure time decreased from 60 minutes in 2018 to 45 minutes in 2020. Insertions performed in the catheterization laboratory decreased significantly (n=14, 18.9% in 2018 and n=3, 1.9% in 2020; P =
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Tampere Heart Hospital, Elämänaukio 1, Tampere, 33520, Finland, 358 3311716.
- Jamk University of Applied Sciences, Jyväskylä, Finland.
- Medtronic Denmark, Copenhagen, Denmark.
- Medtronic International Trading Sarl, Tolochenaz, Switzerland.
Cite
APA
Vanhala, V., Surakka, O., Multisilta, V., Lundsby Johansen, M., Villinger, J., Nicolle, E., Heikkilä, J., & Korhonen, P. (2025). Efficiency Improvement of the Clinical Pathway in Cardiac Monitor Insertion and Follow-Up: Retrospective Analysis. JMIR Cardio. https://doi.org/10.2196/67774
Vancouver
Vanhala V, Surakka O, Multisilta V, Lundsby Johansen M, Villinger J, Nicolle E, et al. Efficiency Improvement of the Clinical Pathway in Cardiac Monitor Insertion and Follow-Up: Retrospective Analysis. JMIR Cardio. 2025. doi:10.2196/67774
BibTeX
@article{Vanhala2025,
author = {Vanhala, Ville and Surakka, Outi and Multisilta, Vilma and Lundsby Johansen, Mette and Villinger, Jonas and Nicolle, Emmanuelle and Heikkilä, Johanna and Korhonen, Pentti},
title = {Efficiency Improvement of the Clinical Pathway in Cardiac Monitor Insertion and Follow-Up: Retrospective Analysis},
journal = {JMIR Cardio},
year = {2025},
doi = {10.2196/67774}
}
EUVIMED