Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study
JMIR Perioperative Medicine · 2025
DOI: 10.2196/60959 ↗At a glance
Beobachtungsstudie in JMIR Perioperative Medicine, 2025. Written by Daria Amon and 7 co-authors. Institution: Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria. Major MEDLINE topics: Smartphone, Epiretinal Membrane, Vision Disorders, Vision Tests. 24 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
Quality of vision in patients with idiopathic epiretinal membranes (iERMs) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and optical coherence tomography findings, which do not adequately reflect the patient’s functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways.
Objectives
This study is the first to assess the use of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERMs, comparing it with a conventional printed chart.
Methods
This prospective observational study included 27 patients with iERMs with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare Medical Inc) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co, Ltd) tests were performed 3 times before and 3 months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity, optical coherence tomography biomarkers, and subjective perception of metamorphopsia were evaluated.
Results
The mean SHT score significantly ( r =0.686; P 0.75).
Conclusions
The SHT showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in patients with iERMs. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing preoperative triaging and reducing unnecessary visits.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.
- NIHR Biomedical Research Center at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, 11-43 Bath Street Lower Ground Floor, London, EC1V, United Kingdom, 44 207 253 3411.
- Department of Ophthalmology and Optometry, Kepler University Hospital, Linz, Austria.
ORCID profiles: Daria Amon, Christoph Leisser, Andreas Schlatter, Manuel Ruiss, Caroline Pilwachs, Natascha Bayer, Josef Huemer, Oliver Findl
Cite
APA
Amon, D., Leisser, C., Schlatter, A., Ruiss, M., Pilwachs, C., Bayer, N., Huemer, J., & Findl, O. (2025). Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study. JMIR Perioperative Medicine. https://doi.org/10.2196/60959
Vancouver
Amon D, Leisser C, Schlatter A, Ruiss M, Pilwachs C, Bayer N, et al. Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study. JMIR Perioperative Medicine. 2025. doi:10.2196/60959
BibTeX
@article{Amon2025,
author = {Amon, Daria and Leisser, Christoph and Schlatter, Andreas and Ruiss, Manuel and Pilwachs, Caroline and Bayer, Natascha and Huemer, Josef and Findl, Oliver},
title = {Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study},
journal = {JMIR Perioperative Medicine},
year = {2025},
doi = {10.2196/60959}
}
EUVIMED