Usability Testing of a Digitized Interventional Prehabilitation Tool for Health Care Professionals and Patients Before Major Surgeries: Formative and Summative Evaluation
JMIR Formative Research · 2024-12-11 · 8 · e59513
DOI: 10.2196/59513 ↗At a glance
Journal article in JMIR Formative Research, published online on 2024-12-11. Written by Andreas A Schnitzbauer and 8 co-authors. Institution: Department of General, Visceral, Transplant and Thoracic Surgery, Frankfurt University Hospital, Goethe University Frankfurt, Frankfurt, Germany. Major MEDLINE topics: Mobile Applications, Health Personnel. Cited 4 times so far (Crossref); 34 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
The development of a medical device requires strict adherence to regulatory processes. Prehabilitation in this context is a new area in surgery that trains, coaches, and advises patients in mental well-being, nutrition, and physical activity. As staff is permanently drained from clinical care, remote and digital solutions with real-time assessments of data, including patient-related outcome reporting, may simplify preparation before major surgeries.
Objective
This study aimed to evaluate the usability engineering process for the Prehab App, a newly developed medical device, in order to identify and adapt any design and usability flaws found.
Methods
We hypothesized that formative and summative usability testing would achieve 80% interrater and intrarater reliability and consistency and that the safety-relevant scenarios would uncover undetected risks of the medical device (stand-alone software class IIa). In total, 8 experts and 8 laypersons (patients and potential patients) were asked to evaluate paper-based mockups, followed by an evaluation of the minimal viable product (MVP) of the Prehab App at least more than 8 weeks later after instruction and training. The experts had to face 5 and the laypersons 6 usability scenarios. Their evaluations were measured with the Mobile App Rating Scale (MARS) and trustworthiness checklists (range 0-64, with higher scores indicating trustworthiness), and the usability scenarios were evaluated with the After Scenario Questionnaire (ASQ) and a judgment by an observer. The time taken for the scenarios was also recorded.
Results
MARS achieved constant scores of more than 4 out of 5 points for both experts and laypersons. The mean trustworthiness score was 51.3 (SD 2.7) for the experts and 50.8 (SD 2.1) for the laypersons (P=.68) in task I. The interrater correlation, shown by the Fleiss-Kappa value, was 0.87 (range 0.85-0.89) for all raters (N=16), 0.86 (range 0.82-0.91) for the experts (n=8, 50%), and 0.88 (range 0.84-0.93) for the laypersons (n=8, 50%), reflecting almost perfect agreement between the raters. This indicated the high quality of the usability. The usability scenarios were performed with ease, except for the onboarding part, when the wearable was required to be connected; this took a considerable amount of time and was recognized as a challenge to good usability.
Conclusions
The formative and summative evaluation of the Prehab App design resulted in good-to-acceptable results of the design and usability of the critical and safety-relevant areas of the medical device and stand-alone software. Usability testing improves medical devices early in the design and development process, reduces errors, and mitigates risks, and in this study, it delivered a profound ethical and medical justification for a randomized controlled trial (RCT) of the Prehab App in a remote setting as a next step in the development process. Trial Registration German Registry for Clinical Trials (DRKS00026985); https://drks.de/search/en/trial/DRKS00026985
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of General, Visceral, Transplant and Thoracic Surgery, Frankfurt University Hospital, Goethe University Frankfurt, Frankfurt, Germany.
- Institute of Sports Medicine, Goethe University Frankfurt/Main, Frankfurt, Germany.
- Faculty for Applied Informatics, Hochschule Heilbronn, Heilbronn, Germany.
- Department of Pain Medicine, Hospital Landsberg am Lech, Landsberg am Lech, Germany.
ORCID profiles: Andreas A Schnitzbauer, Charlotte Detemble, Sara Fatima Faqar-Uz-Zaman, Julia Dreilich, Lisa Mohr, Svenja Sliwinski, Dora Zmuc, Mark Siller, Johannes Fleckenstein
Cite
APA
Schnitzbauer, A. A., Detemble, C., Faqar-Uz-Zaman, S. F., Dreilich, J., Mohr, L., Sliwinski, S., Zmuc, D., Siller, M., & Fleckenstein, J. (2024). Usability Testing of a Digitized Interventional Prehabilitation Tool for Health Care Professionals and Patients Before Major Surgeries: Formative and Summative Evaluation. JMIR Formative Research, 8, e59513. https://doi.org/10.2196/59513
Vancouver
Schnitzbauer AA, Detemble C, Faqar-Uz-Zaman SF, Dreilich J, Mohr L, Sliwinski S, et al. Usability Testing of a Digitized Interventional Prehabilitation Tool for Health Care Professionals and Patients Before Major Surgeries: Formative and Summative Evaluation. JMIR Formative Research. 2024;8:e59513. doi:10.2196/59513
BibTeX
@article{Schnitzbauer2024,
author = {Schnitzbauer, Andreas A and Detemble, Charlotte and Faqar-Uz-Zaman, Sara Fatima and Dreilich, Julia and Mohr, Lisa and Sliwinski, Svenja and Zmuc, Dora and Siller, Mark and Fleckenstein, Johannes},
title = {Usability Testing of a Digitized Interventional Prehabilitation Tool for Health Care Professionals and Patients Before Major Surgeries: Formative and Summative Evaluation},
journal = {JMIR Formative Research},
year = {2024},
volume = {8},
pages = {e59513},
doi = {10.2196/59513}
}
EUVIMED