Scoping Review in Journal of Medical Internet Research, published online on 2024-11-19. Written by Pin Zhong Chan and 3 co-authors. Institution: Department of Nursing, Ng Teng Fong General Hospital, Singapore, Singapore. Major MEDLINE topics: Artificial Intelligence, Blood Glucose Self-Monitoring. Cited 31 times so far (Crossref); 73 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Current blood glucose monitoring (BGM) methods are often invasive and require repetitive pricking of a finger to obtain blood samples, predisposing individuals to pain, discomfort, and infection. Noninvasive blood glucose monitoring (NIBGM) is ideal for minimizing discomfort, reducing the risk of infection, and increasing convenience.

Objective

This review aimed to map the use cases of artificial intelligence (AI) in NIBGM.

Methods

A systematic scoping review was conducted according to the Arksey O’Malley five-step framework. Eight electronic databases (CINAHL, Embase, PubMed, Web of Science, Scopus, The Cochrane-Central Library, ACM Digital Library, and IEEE Xplore) were searched from inception until February 8, 2023. Study selection was conducted by 2 independent reviewers, descriptive analysis was conducted, and findings were presented narratively. Study characteristics (author, country, type of publication, study design, population characteristics, mean age, types of noninvasive techniques used, and application, as well as characteristics of the BGM systems) were extracted independently and cross-checked by 2 investigators. Methodological quality appraisal was conducted using the Checklist for assessment of medical AI.

Results

A total of 33 papers were included, representing studies from Asia, the United States, Europe, the Middle East, and Africa published between 2005 and 2023. Most studies used optical techniques (n=19, 58%) to estimate blood glucose levels (n=27, 82%). Others used electrochemical sensors (n=4), imaging (n=2), mixed techniques (n=2), and tissue impedance (n=1). Accuracy ranged from 35.56% to 94.23% and Clarke error grid (A+B) ranged from 86.91% to 100%. The most popular machine learning algorithm used was random forest (n=10) and the most popular deep learning model was the artificial neural network (n=6). The mean overall checklist for assessment of medical AI score on the included papers was 33.5 (SD 3.09), suggesting an average of medium quality. The studies reviewed demonstrate that some AI techniques can accurately predict glucose levels from noninvasive sources while enhancing comfort and ease of use for patients. However, the overall range of accuracy was wide due to the heterogeneity of models and input data.

Conclusions

Efforts are needed to standardize and regulate the use of AI technologies in BGM, as well as develop consensus guidelines and protocols to ensure the quality and safety of AI-assisted monitoring systems. The use of AI for NIBGM is a promising area of research that has the potential to revolutionize diabetes management.

Subjects

MeSH terms (MEDLINE)

Artificial IntelligenceBlood Glucose Self-MonitoringHumansBlood Glucose

Author keywords

accuracyartificial intelligenceblood glucosedeep learningdiabeteshealth informaticsheterogeneitymachine learningmanagementmobile phonemonitoringnoninvasivescoping reviewself-monitoring

Substances

Blood Glucose

Authors and institutions

  • Department of Nursing, Ng Teng Fong General Hospital, Singapore, Singapore.
  • Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
  • Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland.
  • Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.

ORCID profiles: Pin Zhong Chan, Eric Jin, Miia Jansson, Han Shi Jocelyn Chew

Cite

APA

Chan, P. Z., Jin, E., Jansson, M., & Chew, H. S. J. (2024). AI-Based Noninvasive Blood Glucose Monitoring: Scoping Review. Journal of Medical Internet Research, 26, e58892. https://doi.org/10.2196/58892

Vancouver

Chan PZ, Jin E, Jansson M, Chew HSJ. AI-Based Noninvasive Blood Glucose Monitoring: Scoping Review. Journal of Medical Internet Research. 2024;26:e58892. doi:10.2196/58892

BibTeX
@article{Chan2024,
  author = {Chan, Pin Zhong and Jin, Eric and Jansson, Miia and Chew, Han Shi Jocelyn},
  title = {AI-Based Noninvasive Blood Glucose Monitoring: Scoping Review},
  journal = {Journal of Medical Internet Research},
  year = {2024},
  volume = {26},
  pages = {e58892},
  doi = {10.2196/58892}
}
Start for free →