Feasibility of Monitoring Heart and Respiratory Rates Using Nonwearable Devices and Consistency of the Measured Parameters: Pilot Feasibility Study
JMIR Human Factors · 08.10.2024 · 11 · e56547-e56547
DOI: 10.2196/56547 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR Human Factors, online erschienen am 08.10.2024. Verfasst von Kasumi Ikuta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Home Health and Palliative Care Nursing, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Bunkyo-Ku, Japan. Hauptthemen laut MEDLINE: Feasibility Studies, Respiratory Rate, Heart Rate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
As Japan is the world’s fastest-aging society with a declining population, it is challenging to secure human resources for care providers. Therefore, the Japanese government is promoting digital transformation and the use of nursing care equipment, including nonwearable devices that monitor heart and respiratory rates. However, the feasibility of monitoring heart and respiratory rates with nonwearable devices and the consistency of the rates measured have not been reported.
Objective
In this study, we focused on a sheet-type nonwearable device (Safety Sheep Sensor) introduced in many nursing homes. We evaluated the feasibility of monitoring heart rate (HR) and respiratory rate (RR) continuously using nonwearable devices and the consistency of the HR and RR measured.
Methods
A sheet-type nonwearable device that measured HR and RR every minute through body vibrations was placed under the mattress of each participant. The participants in study 1 were healthy individuals aged 20‐60 years (n=21), while those in study 2 were older adults living in multidwelling houses and required nursing care (n=20). The HR was measured using standard methods by the nurse and using the wearable device (Silmee Bar-type Lite sensor), and RR was measured by the nurse. The primary outcome was the mean difference in HR and RR between nonwearable devices and standard methods.
Results
The mean difference in HR was −0.32 (SD 3.12) in study 1 and 0.04 (SD: 3.98) in study 2; both the differences were within the predefined accepted discrepancies (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Home Health and Palliative Care Nursing, Graduate School of Health Care Sciences, Tokyo Medical and Dental University, Bunkyo-Ku, Japan.
ORCID-Profile: Kasumi Ikuta, Miya Aishima, Maiko Noguchi-Watanabe, Sakiko Fukui
Zitieren
APA
Ikuta, K., Aishima, M., Noguchi-Watanabe, M., & Fukui, S. (2024). Feasibility of Monitoring Heart and Respiratory Rates Using Nonwearable Devices and Consistency of the Measured Parameters: Pilot Feasibility Study. JMIR Human Factors, 11, e56547-e56547. https://doi.org/10.2196/56547
Vancouver
Ikuta K, Aishima M, Noguchi-Watanabe M, Fukui S. Feasibility of Monitoring Heart and Respiratory Rates Using Nonwearable Devices and Consistency of the Measured Parameters: Pilot Feasibility Study. JMIR Human Factors. 2024;11:e56547-e56547. doi:10.2196/56547
BibTeX
@article{Ikuta2024,
author = {Ikuta, Kasumi and Aishima, Miya and Noguchi-Watanabe, Maiko and Fukui, Sakiko},
title = {Feasibility of Monitoring Heart and Respiratory Rates Using Nonwearable Devices and Consistency of the Measured Parameters: Pilot Feasibility Study},
journal = {JMIR Human Factors},
year = {2024},
volume = {11},
pages = {e56547--e56547},
doi = {10.2196/56547}
}