Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study
JMIR mHealth and uHealth · 27.08.2024 · 12 · e53643
DOI: 10.2196/53643 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR mHealth and uHealth, online erschienen am 27.08.2024. Verfasst von Kiran K G Ravindran und 6 weiteren Autor:innen. Beteiligte Einrichtung: Surrey Sleep Research Centre, Guildford, United Kingdom. Hauptthemen laut MEDLINE: Heart Rate, Respiratory Rate. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Medical Research Council.
Themen: Digitalisierung in der Pflege
Abstract (Originalsprache)
Background
Longitudinal monitoring of vital signs provides a method for identifying changes to general health in an individual, particularly in older adults. The nocturnal sleep period provides a convenient opportunity to assess vital signs. Contactless technologies that can be embedded into the bedroom environment are unintrusive and burdenless and have the potential to enable seamless monitoring of vital signs. To realize this potential, these technologies need to be evaluated against gold standard measures and in relevant populations.
Objective
We aimed to evaluate the accuracy of heart rate and breathing rate measurements of 3 contactless technologies (2 undermattress trackers, Withings Sleep Analyzer [WSA] and Emfit QS [Emfit]; and a bedside radar, Somnofy) in a sleep laboratory environment and assess their potential to capture vital signs in a real-world setting.
Methods
Data were collected from 35 community-dwelling older adults aged between 65 and 83 (mean 70.8, SD 4.9) years (men: n=21, 60%) during a 1-night clinical polysomnography (PSG) test in a sleep laboratory, preceded by 7 to 14 days of data collection at home. Several of the participants (20/35, 57%) had health conditions, including type 2 diabetes, hypertension, obesity, and arthritis, and 49% (17) had moderate to severe sleep apnea, while 29% (n=10) had periodic leg movement disorder. The undermattress trackers provided estimates of both heart rate and breathing rate, while the bedside radar provided only the breathing rate. The accuracy of the heart rate and breathing rate estimated by the devices was compared with PSG electrocardiogram-derived heart rate (beats per minute) and respiratory inductance plethysmography thorax-derived breathing rate (cycles per minute), respectively. We also evaluated breathing disturbance indexes of snoring and the apnea-hypopnea index, available from the WSA.
Results
All 3 contactless technologies provided acceptable accuracy in estimating heart rate (mean absolute error
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Surrey Sleep Research Centre, Guildford, United Kingdom.
- UK Dementia Research Institute, Care Research and Technology Centre at Imperial College, London, United Kingdom, and the University of Surrey, Guildford, London, United Kingdom.
- Surrey Clinical Research Facility, University of Surrey, Guildford, United Kingdom.
- NIHR Royal Surrey Clinical Research Facility, Guildford, United Kingdom.
ORCID-Profile: Kiran K G Ravindran, Ciro Della Monica, Giuseppe Atzori, Damion Lambert, Hana Hassanin, Victoria Revell, Derk-Jan Dijk
Förderung
- Medical Research Council
Zitieren
APA
G Ravindran, K. K., Della Monica, C., Atzori, G., Lambert, D., Hassanin, H., Revell, V., & Dijk, D. J. (2024). Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study. JMIR mHealth and uHealth, 12, e53643. https://doi.org/10.2196/53643
Vancouver
G Ravindran KK, Della Monica C, Atzori G, Lambert D, Hassanin H, Revell V, et al. Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study. JMIR mHealth and uHealth. 2024;12:e53643. doi:10.2196/53643
BibTeX
@article{GRavindran2024,
author = {G Ravindran, Kiran K and Della Monica, Ciro and Atzori, Giuseppe and Lambert, Damion and Hassanin, Hana and Revell, Victoria and Dijk, Derk-Jan},
title = {Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study},
journal = {JMIR mHealth and uHealth},
year = {2024},
volume = {12},
pages = {e53643},
doi = {10.2196/53643}
}