EUVIMEDOpdag EUVIMED
Randomisierte kontrollierte StudieOpen access

Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial

Jiamin Wang iD, Meihua Ji iD, Yuan Han iD, Ying Wu iD

JMIR Aging · 2024-01-24 · 7 · e51264-e51264

DOI: 10.2196/51264 ↗

At a glance

Randomisierte kontrollierte Studie in JMIR Aging, published online on 2024-01-24. Written by Jiamin Wang and 3 co-authors. Institution: School of Nursing, Beijing University of Chinese Medicine, Beijing, China. Major MEDLINE topics: Delirium, Mobile Applications, Decision Support Systems, Clinical. Cited 6 times so far (Crossref); 35 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The 3-Minute Diagnostic Interview for Confusion Assessment Method–Defined Delirium (3D-CAM) is an instrument specially developed for the assessment of delirium in general wards, with high reported sensitivity and specificity. However, the use of the 3D-CAM by bedside nurses in routine practice showed relatively poor usability, with multiple human errors during assessment.

Objective

This study aimed to develop a mobile app–based delirium assessment tool based on the 3D-CAM and evaluate its usability among older patients by bedside nurses.

Methods

The Delirium Assessment Tool With Decision Support Based on the 3D-CAM (3D-DST) was developed to address existing issues of the 3D-CAM and optimize the assessment process. Following a randomized crossover design, questionnaires were used to evaluate the usability of the 3D-DST among older adults by bedside nurses. Meanwhile, the performances of both the 3D-DST and the 3D-CAM paper version, including the assessment completion rate, time required for completing the assessment, and the number of human errors made by nurses during assessment, were recorded, and their differences were compared.

Results

The 3D-DST included 3 assessment modules, 9 evaluation interfaces, and 16 results interfaces, with built-in reminders to guide nurses in completing the delirium assessment. In the usability testing, a total of 432 delirium assessments (216 pairs) on 148 older adults were performed by 72 bedside nurses with the 3D-CAM paper version and the 3D-DST. Compared to the 3D-CAM paper version, the mean usability score was significantly higher when using the 3D-DST (4.35 vs 3.40; P

Subjects

MeSH terms (MEDLINE)

DeliriumMobile ApplicationsDecision Support Systems, ClinicalHumansAgedCross-Over StudiesUser-Centered DesignUser-Computer InterfaceReproducibility of Results

Author keywords

3-Minute Diagnostic Interview for Confusion Assessment Method-Defined Delirium3D-CAMclinical decision support systemdeliriumnurseolder adults

Authors and institutions

  • School of Nursing, Beijing University of Chinese Medicine, Beijing, China.
  • School of Nursing, Capital Medical University, Beijing, China.
  • Peking University First Hospital, Beijing, China.

ORCID profiles: Jiamin Wang, Meihua Ji, Yuan Han, Ying Wu

Cite

APA

Wang, J., Ji, M., Han, Y., & Wu, Y. (2024). Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial. JMIR Aging, 7, e51264-e51264. https://doi.org/10.2196/51264

Vancouver

Wang J, Ji M, Han Y, Wu Y. Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial. JMIR Aging. 2024;7:e51264-e51264. doi:10.2196/51264

BibTeX
@article{Wang2024,
  author = {Wang, Jiamin and Ji, Meihua and Han, Yuan and Wu, Ying},
  title = {Development and Usability Testing of a Mobile App–Based Clinical Decision Support System for Delirium: Randomized Crossover Trial},
  journal = {JMIR Aging},
  year = {2024},
  volume = {7},
  pages = {e51264--e51264},
  doi = {10.2196/51264}
}
Start for free →