EUVIMEDOntdek EUVIMED
Open access

Open-Source, Step-Counting Algorithm for Smartphone Data Collected in Clinical and Nonclinical Settings: Algorithm Development and Validation Study

Marcin Straczkiewicz iD, Nancy L Keating iD, Embree Thompson iD, Ursula A Matulonis iD, Susana M Campos iD, Alexi A Wright iD, Jukka-Pekka Onnela iD

JMIR Cancer · 2023-11-15 · 9 · e47646

DOI: 10.2196/47646 ↗

At a glance

Journal article in JMIR Cancer, published online on 2023-11-15. Written by Marcin Straczkiewicz and 6 co-authors. Institution: Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, MA, United States. Cited 17 times so far (Crossref); 50 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, NHLBI NIH HHS, NINR NIH HHS.

SamenvattingSubjectsBibliografische gegevensCiteRelated studies

Abstract (original language)

Background

Step counts are increasingly used in public health and clinical research to assess well-being, lifestyle, and health status. However, estimating step counts using commercial activity trackers has several limitations, including a lack of reproducibility, generalizability, and scalability. Smartphones are a potentially promising alternative, but their step-counting algorithms require robust validation that accounts for temporal sensor body location, individual gait characteristics, and heterogeneous health states.

Objective

Our goal was to evaluate an open-source, step-counting method for smartphones under various measurement conditions against step counts estimated from data collected simultaneously from different body locations (“cross-body” validation), manually ascertained ground truth (“visually assessed” validation), and step counts from a commercial activity tracker (Fitbit Charge 2) in patients with advanced cancer (“commercial wearable” validation).

Methods

We used 8 independent data sets collected in controlled, semicontrolled, and free-living environments with different devices (primarily Android smartphones and wearable accelerometers) carried at typical body locations. A total of 5 data sets (n=103) were used for cross-body validation, 2 data sets (n=107) for visually assessed validation, and 1 data set (n=45) was used for commercial wearable validation. In each scenario, step counts were estimated using a previously published step-counting method for smartphones that uses raw subsecond-level accelerometer data. We calculated the mean bias and limits of agreement (LoA) between step count estimates and validation criteria using Bland-Altman analysis.

Results

In the cross-body validation data sets, participants performed 751.7 (SD 581.2) steps, and the mean bias was –7.2 (LoA –47.6, 33.3) steps, or –0.5%. In the visually assessed validation data sets, the ground truth step count was 367.4 (SD 359.4) steps, while the mean bias was –0.4 (LoA –75.2, 74.3) steps, or 0.1%. In the commercial wearable validation data set, Fitbit devices indicated mean step counts of 1931.2 (SD 2338.4), while the calculated bias was equal to –67.1 (LoA –603.8, 469.7) steps, or a difference of 3.4%.

Conclusions

This study demonstrates that our open-source, step-counting method for smartphone data provides reliable step counts across sensor locations, measurement scenarios, and populations, including healthy adults and patients with cancer.

Subjects

Author keywords

accelerometercanceropen-sourcesmartphonestep countvalidationwearable

Authors and institutions

  • Department of Biostatistics, Harvard T.H. Chan School of Public Health, Boston, MA, United States.
  • Department of Health Care Policy, Harvard Medical School, Boston, MA, United States.
  • Division of General Internal Medicine, Brigham and Women's Hospital, Boston, MA, United States.
  • Dana Farber Cancer Institute, Harvard Medical School, Boston, MA, United States.

ORCID profiles: Marcin Straczkiewicz, Nancy L Keating, Embree Thompson, Ursula A Matulonis, Susana M Campos, Alexi A Wright, Jukka-Pekka Onnela

Funding

  • NCI NIH HHS
  • NHLBI NIH HHS
  • NINR NIH HHS
  • NIMHD NIH HHS
  • NIMH NIH HHS

Cite

APA

Straczkiewicz, M., Keating, N. L., Thompson, E., Matulonis, U. A., Campos, S. M., Wright, A. A., & Onnela, J. P. (2023). Open-Source, Step-Counting Algorithm for Smartphone Data Collected in Clinical and Nonclinical Settings: Algorithm Development and Validation Study. JMIR Cancer, 9, e47646. https://doi.org/10.2196/47646

Vancouver

Straczkiewicz M, Keating NL, Thompson E, Matulonis UA, Campos SM, Wright AA, et al. Open-Source, Step-Counting Algorithm for Smartphone Data Collected in Clinical and Nonclinical Settings: Algorithm Development and Validation Study. JMIR Cancer. 2023;9:e47646. doi:10.2196/47646

BibTeX
@article{Straczkiewicz2023,
  author = {Straczkiewicz, Marcin and Keating, Nancy L and Thompson, Embree and Matulonis, Ursula A and Campos, Susana M and Wright, Alexi A and Onnela, Jukka-Pekka},
  title = {Open-Source, Step-Counting Algorithm for Smartphone Data Collected in Clinical and Nonclinical Settings: Algorithm Development and Validation Study},
  journal = {JMIR Cancer},
  year = {2023},
  volume = {9},
  pages = {e47646},
  doi = {10.2196/47646}
}
Start for free →