Contactless Monitoring System Versus Gold Standard for Respiratory Rate Monitoring in Emergency Department Patients: Pilot Comparison Study
JMIR Formative Research · 2024-02-16 · 8 · e44717
DOI: 10.2196/44717 ↗At a glance
Journal article in JMIR Formative Research, published online on 2024-02-16. Written by Charlotte E Goldfine and 5 co-authors. Institution: Division of Medical Toxicology, Department of Emergency Medicine, Brigham and Women's Hospital, Boston, MA, United States. Cited 8 times so far (Crossref); 21 references. The full text is freely available in PubMed Central. Funded by: NIDA NIH HHS.
Abstract (original language)
Background
Respiratory rate is a crucial indicator of disease severity yet is the most neglected vital sign. Subtle changes in respiratory rate may be the first sign of clinical deterioration in a variety of disease states. Current methods of respiratory rate monitoring are labor-intensive and sensitive to motion artifacts, which often leads to inaccurate readings or underreporting; therefore, new methods of respiratory monitoring are needed. The PulsON 440 (P440; TSDR Ultra Wideband Radios and Radars) radar module is a contactless sensor that uses an ultrawideband impulse radar to detect respiratory rate. It has previously demonstrated accuracy in a laboratory setting and may be a useful alternative for contactless respiratory monitoring in clinical settings; however, it has not yet been validated in a clinical setting.
Objective
The goal of this study was to (1) compare the P440 radar module to gold standard manual respiratory rate monitoring and standard of care telemetry respiratory monitoring through transthoracic impedance plethysmography and (2) compare the P440 radar to gold standard measurements of respiratory rate in subgroups based on sex and disease state.
Methods
This was a pilot study of adults aged 18 years or older being monitored in the emergency department. Participants were monitored with the P440 radar module for 2 hours and had gold standard (manual respiratory counting) and standard of care (telemetry) respiratory rates recorded at 15-minute intervals during that time. Respiratory rates between the P440, gold standard, and standard telemetry were compared using Bland-Altman plots and intraclass correlation coefficients.
Results
A total of 14 participants were enrolled in the study. The P440 and gold standard Bland-Altman analysis showed a bias of –0.76 (–11.16 to 9.65) and an intraclass correlation coefficient of 0.38 (95% CI 0.06-0.60). The P440 and gold standard had the best agreement at normal physiologic respiratory rates. There was no change in agreement between the P440 and the gold standard when grouped by admitting diagnosis or sex.
Conclusions
Although the P440 did not have statistically significant agreement with gold standard respiratory rate monitoring, it did show a trend of increased agreement in the normal physiologic range, overestimating at low respiratory rates, and underestimating at high respiratory rates. This trend is important for adjusting future models to be able to accurately detect respiratory rates. Once validated, the contactless respiratory monitor provides a unique solution for monitoring patients in a variety of settings.
Subjects
Author keywords
Authors and institutions
- Division of Medical Toxicology, Department of Emergency Medicine, Brigham and Women's Hospital, Boston, MA, United States.
- Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, MA, United States.
- Department of Emergency Medicine, University of Massachusetts Chan Medical School, Worcester, MA, United States.
- Halıcıoğlu Data Science Institute, University of California San Diego, San Diego, CA, United States.
ORCID profiles: Charlotte E Goldfine, Md Farhan Tasnim Oshim, Brittany P Chapman, Deepak Ganesan, Tauhidur Rahman, Stephanie P Carreiro
Funding
- NIDA NIH HHS
Cite
APA
Goldfine, C. E., Oshim, M. F. T., Chapman, B. P., Ganesan, D., Rahman, T., & Carreiro, S. P. (2024). Contactless Monitoring System Versus Gold Standard for Respiratory Rate Monitoring in Emergency Department Patients: Pilot Comparison Study. JMIR Formative Research, 8, e44717. https://doi.org/10.2196/44717
Vancouver
Goldfine CE, Oshim MFT, Chapman BP, Ganesan D, Rahman T, Carreiro SP. Contactless Monitoring System Versus Gold Standard for Respiratory Rate Monitoring in Emergency Department Patients: Pilot Comparison Study. JMIR Formative Research. 2024;8:e44717. doi:10.2196/44717
BibTeX
@article{Goldfine2024,
author = {Goldfine, Charlotte E and Oshim, Md Farhan Tasnim and Chapman, Brittany P and Ganesan, Deepak and Rahman, Tauhidur and Carreiro, Stephanie P},
title = {Contactless Monitoring System Versus Gold Standard for Respiratory Rate Monitoring in Emergency Department Patients: Pilot Comparison Study},
journal = {JMIR Formative Research},
year = {2024},
volume = {8},
pages = {e44717},
doi = {10.2196/44717}
}
EUVIMED