Wastewater Surveillance for SARS-CoV-2 at Long-Term Care Facilities: Mixed Methods Evaluation
JMIR Public Health and Surveillance · 2023-08-29 · 9 · e44657
DOI: 10.2196/44657 ↗At a glance
Mixed-Methods-Studie in JMIR Public Health and Surveillance, published online on 2023-08-29. Written by James W Keck and 10 co-authors. Institution: Department of Family & Community Medicine, University of Kentucky, Lexington, KY, United States. Major MEDLINE topics: Wastewater, COVID-19. Cited 14 times so far (Crossref); 32 references. The full text is freely available in PubMed Central. Funded by: NIEHS NIH HHS.
Topics: Langzeitpflege
Abstract (original language)
Background
Wastewater surveillance provided early indication of COVID-19 in US municipalities. Residents of long-term care facilities (LTCFs) experienced disproportionate morbidity and mortality early in the COVID-19 pandemic. We implemented LTCF building-level wastewater surveillance for SARS-CoV-2 at 6 facilities in Kentucky to provide early warning of SARS-CoV-2 in populations considered vulnerable.
Objective
This study aims to evaluate the performance of wastewater surveillance for SARS-CoV-2 at LTCFs in Kentucky.
Methods
We conducted a mixed methods evaluation of wastewater surveillance following Centers for Disease Control and Prevention (CDC) guidelines for evaluating public health surveillance systems. Evaluation steps in the CDC guidelines were engaging stakeholders, describing the surveillance system, focusing the evaluation design, gathering credible evidence, and generating conclusions and recommendations. We purposively recruited stakeholders for semistructured interviews and undertook thematic content analysis of interview data. We integrated wastewater, clinical testing, and process data to characterize or calculate 7 surveillance system performance attributes (simplicity, flexibility, data quality, sensitivity and positive predictive value [PPV], timeliness, representativeness, and stability).
Results
We conducted 8 stakeholder interviews. The surveillance system collected wastewater samples (N=811) 2 to 4 times weekly at 6 LTCFs in Kentucky from March 2021 to February 2022. Synthesis of credible evidence indicated variable surveillance performance. Regarding simplicity, surveillance implementation required moderate human resource and technical capacity. Regarding flexibility, the system efficiently adjusted surveillance frequency and demonstrated the ability to detect additional pathogens of interest. Regarding data quality, software identified errors in wastewater sample metadata entry (110/3120, 3.53% of fields), technicians identified polymerase chain reaction data issues (140/7734, 1.81% of reactions), and staff entered all data corrections into a log. Regarding sensitivity and PPV, using routine LTCF SARS-CoV-2 clinical testing results as the gold standard, a wastewater SARS-CoV-2 signal of >0 RNA copies/mL was 30.6% (95% CI 24.4%-36.8%) sensitive and 79.7% (95% CI 76.4%-82.9%) specific for a positive clinical test at the LTCF. The PPV of the wastewater signal was 34.8% (95% CI 27.9%-41.7%) at >0 RNA copies/mL and increased to 75% (95% CI 60%-90%) at >250 copies/mL. Regarding timeliness, stakeholders received surveillance data 24 to 72 hours after sample collection, with delayed reporting because of the lack of weekend laboratory staff. Regarding representativeness, stakeholders identified challenges delineating the population contributing to LTCF wastewater because of visitors, unknown staff toileting habits, and the use of adult briefs by some residents preventing their waste from entering the sewer system. Regarding stability, the reoccurring cost to conduct 1 day of wastewater surveillance at 1 facility was approximately US $144.50, which included transportation, labor, and materials expenses.
Conclusions
The LTCF wastewater surveillance system demonstrated mixed performance per CDC criteria. Stakeholders found surveillance feasible and expressed optimism regarding its potential while also recognizing challenges in interpreting and acting on surveillance data.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Family & Community Medicine, University of Kentucky, Lexington, KY, United States.
- College of Medicine - Northern Kentucky Campus, University of Kentucky, Highland Heights, KY, United States.
- Department of Family and Community Medicine, University of Kentucky, Lexington, KY, United States.
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, United States.
- Department of Mechanical Engineering, University of Kentucky, Lexington, KY, United States.
- Department of Biostatistics, University of Kentucky, Lexington, KY, United States.
ORCID profiles: James W Keck, Jess Lindner, Matthew Liversedge, Blazan Mijatovic, Cullen Olsson, William Strike, Anni Noble, Reuben Adatorwovor, Parker Lacy, Ted Smith, Scott M Berry
Funding
- NIEHS NIH HHS
Cite
APA
Keck, J. W., Lindner, J., Liversedge, M., Mijatovic, B., Olsson, C., Strike, W., Noble, A., Adatorwovor, R., Lacy, P., Smith, T., & Berry, S. M. (2023). Wastewater Surveillance for SARS-CoV-2 at Long-Term Care Facilities: Mixed Methods Evaluation. JMIR Public Health and Surveillance, 9, e44657. https://doi.org/10.2196/44657
Vancouver
Keck JW, Lindner J, Liversedge M, Mijatovic B, Olsson C, Strike W, et al. Wastewater Surveillance for SARS-CoV-2 at Long-Term Care Facilities: Mixed Methods Evaluation. JMIR Public Health and Surveillance. 2023;9:e44657. doi:10.2196/44657
BibTeX
@article{Keck2023,
author = {Keck, James W and Lindner, Jess and Liversedge, Matthew and Mijatovic, Blazan and Olsson, Cullen and Strike, William and Noble, Anni and Adatorwovor, Reuben and Lacy, Parker and Smith, Ted and Berry, Scott M},
title = {Wastewater Surveillance for SARS-CoV-2 at Long-Term Care Facilities: Mixed Methods Evaluation},
journal = {JMIR Public Health and Surveillance},
year = {2023},
volume = {9},
pages = {e44657},
doi = {10.2196/44657}
}
EUVIMED