EUVIMEDEUVIMED entdecken
Open Access

Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study

Mathilde C van Rossum iD, Robin E M Bekhuis iD, Ying Wang iD, Johannes H Hegeman iD, Ellis C Folbert iD, Miriam M R Vollenbroek-Hutten iD, Cornelis J Kalkman iD, Ewout A Kouwenhoven iD, Hermie J Hermens iD

JMIR Perioperative Medicine · 30.08.2023 · 6 · e44483

DOI: 10.2196/44483 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JMIR Perioperative Medicine, online erschienen am 30.08.2023. Verfasst von Mathilde C van Rossum und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown.

Objective

This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms).

Methods

Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR).

Results

The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P

Schlagwörter

Stichwörter der Autor:innen

clinical alarmsearly warning scoresperioperative nursingphysiological monitoringpostoperative complicationstelemedicinevital signs

Autor:innen und Institutionen

  • Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands.
  • Department of Cardiovascular and Respiratory Physiology, University of Twente, Enschede, Netherlands.
  • Department of Surgery, Hospital Group Twente, Almelo, Netherlands.
  • Hospital Group Twente Academy, Hospital Group Twente, Almelo, Netherlands.
  • Department of Anesthesiology, University Medical Center Utrecht, Utrecht, Netherlands.

ORCID-Profile: Mathilde C van Rossum, Robin E M Bekhuis, Ying Wang, Johannes H Hegeman, Ellis C Folbert, Miriam M R Vollenbroek-Hutten, Cornelis J Kalkman, Ewout A Kouwenhoven, Hermie J Hermens

Zitieren

APA

van Rossum, M. C., Bekhuis, R. E. M., Wang, Y., Hegeman, J. H., Folbert, E. C., Vollenbroek-Hutten, M. M. R., Kalkman, C. J., Kouwenhoven, E. A., & Hermens, H. J. (2023). Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study. JMIR Perioperative Medicine, 6, e44483. https://doi.org/10.2196/44483

Vancouver

van Rossum MC, Bekhuis REM, Wang Y, Hegeman JH, Folbert EC, Vollenbroek-Hutten MMR, et al. Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study. JMIR Perioperative Medicine. 2023;6:e44483. doi:10.2196/44483

BibTeX
@article{vanRossum2023,
  author = {van Rossum, Mathilde C and Bekhuis, Robin E M and Wang, Ying and Hegeman, Johannes H and Folbert, Ellis C and Vollenbroek-Hutten, Miriam M R and Kalkman, Cornelis J and Kouwenhoven, Ewout A and Hermens, Hermie J},
  title = {Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study},
  journal = {JMIR Perioperative Medicine},
  year = {2023},
  volume = {6},
  pages = {e44483},
  doi = {10.2196/44483}
}