Equity-Driven Sensing System for Measuring Skin Tone–Calibrated Peripheral Blood Oxygen Saturation (OptoBeat): Development, Design, and Evaluation Study
JMIR Biomedical Engineering · 22.04.2022 · 7 (1) · e34934
DOI: 10.2196/34934 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR Biomedical Engineering, online erschienen am 22.04.2022. Verfasst von Alexander T Adams und 5 weiteren Autor:innen. Beteiligte Einrichtung: Information Science, Cornell Tech, New York, NY, United States. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Many commodity pulse oximeters are insufficiently calibrated for patients with darker skin. We demonstrate a quantitative measurement of this disparity in peripheral blood oxygen saturation (SpO2) with a controlled experiment. To mitigate this, we present OptoBeat, an ultra–low-cost smartphone-based optical sensing system that captures SpO2 and heart rate while calibrating for differences in skin tone. Our sensing system can be constructed from commodity components and 3D-printed clips for approximately US $1. In our experiments, we demonstrate the efficacy of the OptoBeat system, which can measure SpO2 within 1% of the ground truth in levels as low as 75%.
Objective
The objective of this work is to test the following hypotheses and implement an ultra–low-cost smartphone adapter to measure SpO2: skin tone has a significant effect on pulse oximeter measurements (hypothesis 1), images of skin tone can be used to calibrate pulse oximeter error (hypothesis 2), and SpO2 can be measured with a smartphone camera using the screen as a light source (hypothesis 3).
Methods
Synthetic skin with the same optical properties as human skin was used in ex vivo experiments. A skin tone scale was placed in images for calibration and ground truth. To achieve a wide range of SpO2 for measurement, we reoxygenated sheep blood and pumped it through synthetic arteries. A custom optical system was connected from the smartphone screen (flashing red and blue) to the analyte and into the phone’s camera for measurement.
Results
The 3 skin tones were accurately classified according to the Fitzpatrick scale as types 2, 3, and 5. Classification was performed using the Euclidean distance between the measured red, green, and blue values. Traditional pulse oximeter measurements (n=2000) showed significant differences between skin tones in both alternating current and direct current measurements using ANOVA (direct current: F2,5997=3.1170 × 105, P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Information Science, Cornell Tech, New York, NY, United States.
- The Center for the Study of Social Determinants of Health, Meharry Medical College, Nashville, TN, United States.
- Psychiatry and Behavioral Sciences, School of Medicine, Meharry Medical College, Nashville, TN, United States.
- Division of Public Health, School of Graduate Studies and Research, Meharry Medical College, Nashville, TN, United States.
ORCID-Profile: Alexander T Adams, Ilan Mandel, Yixuan Gao, Bryan W Heckman, Rajalakshmi Nandakumar, Tanzeem Choudhury
Zitieren
APA
Adams, A. T., Mandel, I., Gao, Y., Heckman, B. W., Nandakumar, R., & Choudhury, T. (2022). Equity-Driven Sensing System for Measuring Skin Tone–Calibrated Peripheral Blood Oxygen Saturation (OptoBeat): Development, Design, and Evaluation Study. JMIR Biomedical Engineering, 7(1), e34934. https://doi.org/10.2196/34934
Vancouver
Adams AT, Mandel I, Gao Y, Heckman BW, Nandakumar R, Choudhury T. Equity-Driven Sensing System for Measuring Skin Tone–Calibrated Peripheral Blood Oxygen Saturation (OptoBeat): Development, Design, and Evaluation Study. JMIR Biomedical Engineering. 2022;7(1):e34934. doi:10.2196/34934
BibTeX
@article{Adams2022,
author = {Adams, Alexander T and Mandel, Ilan and Gao, Yixuan and Heckman, Bryan W and Nandakumar, Rajalakshmi and Choudhury, Tanzeem},
title = {Equity-Driven Sensing System for Measuring Skin Tone–Calibrated Peripheral Blood Oxygen Saturation (OptoBeat): Development, Design, and Evaluation Study},
journal = {JMIR Biomedical Engineering},
year = {2022},
volume = {7},
number = {1},
pages = {e34934},
doi = {10.2196/34934}
}
EUVIMED