A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation
Biosensors · 04.03.2024 · 14 (3) · 132
DOI: 10.3390/bios14030132 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 04.03.2024. Verfasst von Michal Katan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel. Hauptthemen laut MEDLINE: Oxygen Saturation, Biosensing Techniques. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israel Science Foundation, EU COST, COST action.
Abstract (Originalsprache)
Traditional methods for measuring blood oxygen use multiple wavelengths, which produce an intrinsic error due to ratiometric measurements. These methods assume that the absorption changes with the wavelength, but in fact the scattering changes as well and cannot be neglected. We found that if one measures in a specific angle around a cylindrical tissue, called the iso-pathlength (IPL) point, the reemitted light intensity is unaffected by the tissue’s scattering. Therefore, the absorption can be isolated from the scattering, which allows the extraction of the subject’s oxygen saturation. In this work, we designed an optical biosensor for reading the light intensity reemitted from the tissue, using a single light source and multiple photodetectors (PDs), with one of them in the IPL point’s location. Using this bio-device, we developed a methodology to extract the arterial oxygen saturation using a single wavelength light source. We proved this method is not dependent on the light source and is applicable to different measurement locations on the body, with an error of 0.5%. Moreover, we tested thirty-eight males and females with the biosensor under normal conditions. Finally, we show the results of measuring subjects in a hypoxic chamber that simulates extreme conditions with low oxygen.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel.
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel.
ORCID-Profile: Dror Fixler
Förderung
- Israel Science Foundation
- EU COST
- COST action
Zitieren
APA
Katan, M., Pearl, O., Tzroya, A., Duadi, H., & Fixler, D. (2024). A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation. Biosensors, 14(3), 132. https://doi.org/10.3390/bios14030132
Vancouver
Katan M, Pearl O, Tzroya A, Duadi H, Fixler D. A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation. Biosensors. 2024;14(3):132. doi:10.3390/bios14030132
BibTeX
@article{Katan2024,
author = {Katan, Michal and Pearl, Ori and Tzroya, Alon and Duadi, Hamootal and Fixler, Dror},
title = {A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {3},
pages = {132},
doi = {10.3390/bios14030132}
}