EUVIMEDScopri EUVIMED
Crossref

Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study

Leia C Shum, Bulmaro A Valdés, HF Machiel Van der Loos

JMIR Biomedical Engineering · 2019

DOI: 10.2196/12291 ↗

At a glance

Journal article in JMIR Biomedical Engineering, 2019. Written by Leia C Shum and 2 co-authors. Cited 24 times so far (Crossref); 30 references.

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

BACKGROUND As commercial motion tracking technology becomes more readily available, it is necessary to evaluate the accuracy of these systems before using them for biomechanical and motor rehabilitation applications. OBJECTIVE This study aimed to evaluate the relative position accuracy of the Oculus Touch controllers in a 2.4 x 2.4 m play-space. METHODS Static data samples (n=180) were acquired from the Oculus Touch controllers at step sizes ranging from 5 to 500 mm along 16 different points on the play-space floor with graph paper in the x (width), y (height), and z (depth) directions. The data were compared with reference values using measurements from digital calipers, accurate to 0.01 mm; physical blocks, for which heights were confirmed with digital calipers; and for larger step sizes (300 and 500 mm), a ruler with hatch marks to millimeter units. RESULTS It was found that the maximum position accuracy error of the system was 3.5 ± 2.5 mm at the largest step size of 500 mm along the z-axis. When normalized to step size, the largest error found was 12.7 ± 9.9% at the smallest step size in the y-axis at 6.23 mm. When the step size was

Cite

APA

Shum, L. C., Valdés, B. A., & Loos, H. M. V. D. (2019). Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study. JMIR Biomedical Engineering. https://doi.org/10.2196/12291

Vancouver

Shum LC, Valdés BA, Loos HMVD. Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study. JMIR Biomedical Engineering. 2019. doi:10.2196/12291

BibTeX
@article{Shum2019,
  author = {Shum, Leia C and Valdés, Bulmaro A and Loos, HF Machiel Van der},
  title = {Determining the Accuracy of Oculus Touch Controllers for Motor Rehabilitation Applications Using Quantifiable Upper Limb Kinematics: Validation Study},
  journal = {JMIR Biomedical Engineering},
  year = {2019},
  doi = {10.2196/12291}
}
Start for free →