EUVIMEDEUVIMED entdecken
Crossref

Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study

Shravya Reddy, Preeti S Kumar, Vyoma V Grandhi

JMIR Biomedical Engineering · 2018

DOI: 10.2196/11347 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JMIR Biomedical Engineering, 2018. Verfasst von Shravya Reddy und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The proposed experimental design was devised to determine whether a relationship exists between the occlusal load applied and the size of the markings produced from tooth contact when dental articulating paper and T-Scan are interposed alternatively.

Objective

The objective of our study was to compare the relationship between contact markings on an articulating paper and T-Scan for an applied occlusal load.

Methods

In this in vitro study, dentulous maxillary and mandibular dies were mounted on a metal jig and articulating paper and T-Scan sensor were placed alternatively between the casts. Loads simulating occlusal loads began at 25 N and incrementally continued up to 450 N. The resultant markings (180 marks resulting from articulating paper and 138 from T-Scan) were photographed, and the marks were analyzed using MOTIC image analysis and sketching software. Descriptive statistical analyses were performed using one-way analysis of variance, Student t test, and Pearson correlation coefficient method.

Results

Statistical interpretation of the data indicated that with articulating paper, the mark area increased nonlinearly with increasing load and there was a false-positive result. The characteristics of the paper mark appearance did not describe the amount of occlusal load present on a given tooth. The contact marking obtained using T-Scan for an applied occlusal load indicated that the mark area increased with increase in the load and provided more predictable results of actual load content within the occlusal contact.

Conclusions

The size of an articulating paper mark may not be a reliable predictor of the actual load content within the occlusal contact, whereas a T-Scan provides more predictable results of the actual load content within the occlusal contact.

Zitieren

APA

Reddy, S., Kumar, P. S., & Grandhi, V. V. (2018). Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study. JMIR Biomedical Engineering. https://doi.org/10.2196/11347

Vancouver

Reddy S, Kumar PS, Grandhi VV. Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study. JMIR Biomedical Engineering. 2018. doi:10.2196/11347

BibTeX
@article{Reddy2018,
  author = {Reddy, Shravya and Kumar, Preeti S and Grandhi, Vyoma V},
  title = {Relationship Between the Applied Occlusal Load and the Size of Markings Produced Due to Occlusal Contact Using Dental Articulating Paper and T-Scan: Comparative Study},
  journal = {JMIR Biomedical Engineering},
  year = {2018},
  doi = {10.2196/11347}
}
Kostenlos starten →