Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking
Journal of Medical Internet Research · 2026-10-06 · 28 · e110058-e110058
DOI: 10.2196/110058 ↗At a glance
Journal article in Journal of Medical Internet Research, published online on 2026-10-06. Written by Wenze Kan and 2 co-authors. Institution: School of Clinical Medicine, Jiamusi University, Jiamusi, China. Cited 1 times so far (Crossref); 6 references. The full text is freely available in PubMed Central.
Abstract (original language)
UNSTRUCTURED This letter examines the interpretation and clinical translation of a meta-analysis of radiomics-based artificial intelligence (AI) for predicting pathological response after neoadjuvant immunochemotherapy in resectable non–small cell lung cancer. We highlight that the conventional-response comparator combines PERCIST and RECIST 1.1 assessments from the same 36-patient cohort, whereas the AI estimates arise from unmatched cohorts; consequently, the reported denominator and Z tests do not establish comparative superiority. We further consider how restriction to patients who reached resection and variation in imaging timepoints narrow the clinical estimand and limit inference about earlier treatment redirection. Clarification of the RECIST and error-direction examples is also warranted. We propose same-patient comparisons in treatment-initiation cohorts using fixed imaging times, locked thresholds, explicit primary-tumor and nodal labels, and calibration and net-benefit analyses at prespecified clinical thresholds.
Subjects
Author keywords
Authors and institutions
- School of Clinical Medicine, Jiamusi University, Jiamusi, China.
- Department of Radiology, The First Affiliated Hospital of Jiamusi University, Jiamusi, China.
- Department of Radiology, Zaoyang First People's Hospital, 183 Zhongxing Avenue, Zaoyang, Hubei, 441200, China, 86 17346379074.
Cite
APA
Kan, W., Pei, H., & Zhang, M. (2026). Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking. Journal of Medical Internet Research, 28, e110058-e110058. https://doi.org/10.2196/110058
Vancouver
Kan W, Pei H, Zhang M. Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking. Journal of Medical Internet Research. 2026;28:e110058-e110058. doi:10.2196/110058
BibTeX
@article{Kan2026,
author = {Kan, Wenze and Pei, Haoliang and Zhang, Mingxin},
title = {Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking},
journal = {Journal of Medical Internet Research},
year = {2026},
volume = {28},
pages = {e110058--e110058},
doi = {10.2196/110058}
}
EUVIMED