Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking
Journal of Medical Internet Research · 06.10.2026 · 28 · e110058-e110058
DOI: 10.2196/110058 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Internet Research, online erschienen am 06.10.2026. Verfasst von Wenze Kan und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Jiamusi University, Jiamusi, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 6 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
UNSTRUCTURED This letter examines the interpretation and clinical translation of a meta-analysis of radiomics-based artificial intelligence (AI) for predicting pathological response after neoadjuvant immunochemotherapy in resectable non–small cell lung cancer. We highlight that the conventional-response comparator combines PERCIST and RECIST 1.1 assessments from the same 36-patient cohort, whereas the AI estimates arise from unmatched cohorts; consequently, the reported denominator and Z tests do not establish comparative superiority. We further consider how restriction to patients who reached resection and variation in imaging timepoints narrow the clinical estimand and limit inference about earlier treatment redirection. Clarification of the RECIST and error-direction examples is also warranted. We propose same-patient comparisons in treatment-initiation cohorts using fixed imaging times, locked thresholds, explicit primary-tumor and nodal labels, and calibration and net-benefit analyses at prespecified clinical thresholds.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Clinical Medicine, Jiamusi University, Jiamusi, China.
- Department of Radiology, The First Affiliated Hospital of Jiamusi University, Jiamusi, China.
- Department of Radiology, Zaoyang First People's Hospital, 183 Zhongxing Avenue, Zaoyang, Hubei, 441200, China, 86 17346379074.
Zitieren
APA
Kan, W., Pei, H., & Zhang, M. (2026). Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking. Journal of Medical Internet Research, 28, e110058-e110058. https://doi.org/10.2196/110058
Vancouver
Kan W, Pei H, Zhang M. Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking. Journal of Medical Internet Research. 2026;28:e110058-e110058. doi:10.2196/110058
BibTeX
@article{Kan2026,
author = {Kan, Wenze and Pei, Haoliang and Zhang, Mingxin},
title = {Same-Patient, Same–Time Point Evidence for Radiomics Benchmarking},
journal = {Journal of Medical Internet Research},
year = {2026},
volume = {28},
pages = {e110058--e110058},
doi = {10.2196/110058}
}
EUVIMED