Auf einen Blick

6 Chatbots wurden mit 55 COPD-Fragen verglichen. In allen Modellen traten unsichere Antworten auf; die Sicherheitsunterschiede zwischen den Modellen waren nicht signifikant.

Fragestellung

Vergleichen 6 öffentliche LLM-Chatbots bei COPD-Fragen Sicherheit, Genauigkeit, Empathie, Informationsqualität, Quellen-Transparenz, Lesbarkeit und 2-Runden-Stabilität?

Methode

55 englische COPD-Fragen; 6 öffentliche Chatbots; 5 verblindete Rater; erste Runde und zweite Runde als Retest; Vergleich mit GOLD-2026-Referenzstandard.

Ergebnisse

Erste Runde: 330 Antworten. Unsichere Antworten: ChatGPT, Gemini, Copilot und DeepSeek je 4 (7,3 %); Qwen 5 (9,1 %); Doubao 6 (10,9 %). Sicherheitsvergleich: Cochran Q=1.909, df=5; P=.86.

Einschränkungen

Die zweite Runde wurde post hoc nach der ersten Datenerhebung ergänzt.

Schlussfolgerung der Autor:innen

In diesem standardisierten Single-Turn-Fragenset unterschieden sich die Modelle in mehreren Ergebnissen. Alle 6 Modelle gaben potenziell unsichere Ratschläge; für individuelle Entscheidungen wird klinische Aufsicht empfohlen.

Kernaussagen

  • Unsichere Antworten traten in allen 6 Modellen auf.
  • Sicherheitsunterschiede waren statistisch nicht signifikant.
  • 9 Sicherheitsbewertungen änderten sich zwischen den 2 Runden.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

At a glance

Vergleichsstudie in JMIR Medical Informatics, published online on 2026-11-09. Written by Liping Fan and 7 co-authors. Institution: Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou, Henan, China. Major MEDLINE topics: Pulmonary Disease, Chronic Obstructive, Comprehension. 43 references.

Auf einen BlickAbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Large language models (LLMs) are increasingly used for health information, but chronic obstructive pulmonary disease (COPD)–related questions often involve safety-sensitive decisions, including treatment escalation, oxygen therapy, and exacerbation management. Because generative outputs may vary across repeated prompts, response stability is also relevant to comparative evaluation.

Objective

This study aims to compare 6 public-facing LLM chatbots in answering COPD-related public health questions across safety, accuracy, empathy, information quality, source transparency, readability, and 2-round response stability.

Methods

We developed a 55-question English COPD question bank from an initial 108-question pool using web-based retrieval, Google Trends, PubMed-informed topic review, patient education resources, and expert screening. Six public-facing chatbot products were evaluated in a primary first round and a post hoc independent second round, added after first-round data collection, using the same 55 questions. Visible model/mode labels are provided in the supplementary materials. Five blinded raters assessed manually scored outcomes against a Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2026-centered reference standard, and 6 readability indices were calculated. The primary cross-model analysis used the first round; the second round was analyzed as a matched retest sensitivity analysis. Stability was assessed using exact agreement and Cohen κ for safety, quadratic-weighted κ for ordinal ratings, and absolute-agreement single-measure intraclass correlation coefficients (ICCs) for continuous scores and readability indices; 95% CIs used question-level bootstrap resampling.

Results

The first round yielded 330 responses. Unsafe responses occurred in every model: ChatGPT, Gemini, Copilot, and DeepSeek each generated 4 unsafe responses (7.3%); Qwen generated 5 (9.1%); and Doubao generated 6 (10.9%). The overall safety comparison was not statistically significant (Cochran Q=1.909, df=5; P=.86); this finding should not be interpreted as evidence of equivalent safety. Accuracy, empathy, information-quality measures, source-transparency scores, and readability indices differed significantly across models. Across 330 matched question-model pairs, safety classifications agreed in 97.3% of pairs (κ=0.821, 95% CI 0.543-0.979); accuracy and empathy showed weighted κ values of 0.872 and 0.856, respectively; DISCERN (an instrument for judging the quality of written consumer health information on treatment choices) and adapted Ensuring Quality Information for Patients (EQIP) showed ICCs of 0.954 and 0.925. Most readability indices also showed high overall 2-round stability, although model-specific variability remained. Nine safety classifications changed across the 2 rounds (5 from safe to unsafe and 4 from unsafe to safe).

Conclusions

In this standardized single-turn COPD question set, model performance differed across several evaluated outcomes, whereas the first-round safety test neither established a between-model difference nor demonstrated equivalence. All 6 models produced potentially unsafe advice, and 9 safety classifications changed between rounds conducted several months apart despite high pooled agreement. These findings support cautious use of LLMs for supplementary COPD education, with clinician oversight for individualized treatment decisions and ongoing reassessment as public-facing systems change.

Subjects

MeSH terms (MEDLINE)

Pulmonary Disease, Chronic ObstructiveComprehensionLarge Language ModelsHumansCross-Sectional StudiesSurveys and Questionnaires

Author keywords

CHARTCOPDChatbot Assessment Reporting ToolLLMchatbotchronic obstructive pulmonary diseasehealth information qualitylarge language modelpatient educationreadabilitysafety

Authors and institutions

  • Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou, Henan, China.
  • Department of Spine Surgery, The First People's Hospital of Changzhou, Changzhou, Jiangsu, China.
  • Department of Nursing, The First Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou, Henan, China.

ORCID profiles: Liping Fan, Ru Liu, Zhishui Wu, Jingjing Li, Jiao Lei, Qingqing Zhang, Xinghua Li, Yanming Yang

Cite

APA

Fan, L., Liu, R., Wu, Z., Li, J., Lei, J., Zhang, Q., Li, X., & Yang, Y. (2026). Safety, Accuracy, Empathy, Information Quality, and Readability of Chronic Obstructive Pulmonary Disease Health Advice Generated by 6 Large Language Models: Cross-Sectional Comparative Evaluation Study. JMIR Medical Informatics, 14, e104836. https://doi.org/10.2196/104836

Vancouver

Fan L, Liu R, Wu Z, Li J, Lei J, Zhang Q, et al. Safety, Accuracy, Empathy, Information Quality, and Readability of Chronic Obstructive Pulmonary Disease Health Advice Generated by 6 Large Language Models: Cross-Sectional Comparative Evaluation Study. JMIR Medical Informatics. 2026;14:e104836. doi:10.2196/104836

BibTeX
@article{Fan2026,
  author = {Fan, Liping and Liu, Ru and Wu, Zhishui and Li, Jingjing and Lei, Jiao and Zhang, Qingqing and Li, Xinghua and Yang, Yanming},
  title = {Safety, Accuracy, Empathy, Information Quality, and Readability of Chronic Obstructive Pulmonary Disease Health Advice Generated by 6 Large Language Models: Cross-Sectional Comparative Evaluation Study},
  journal = {JMIR Medical Informatics},
  year = {2026},
  volume = {14},
  pages = {e104836},
  doi = {10.2196/104836}
}
Start for free →