Fallbericht in der Zeitschrift Journal of Prosthodontic Research, 2026. Verfasst von Rong Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Na…. Hauptthemen laut MEDLINE: Ketones, Computer-Aided Design, Mandible, Dental Prosthesis Design. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PATIENTS: This report describes the digital workflow for the design and fabrication of a telescopic prosthesis that incorporates a polyetherketoneketone (PEKK) primary crown and PEKK framework to restore multiple teeth in the mandible of a 56-year-old female patient. The process includes intraoral scanning, computer-aided design, digital milling of the telescopic crown and PEKK framework, and 3D printing of the casts. Good retention, mastication, aesthetics, and biological outcomes are observed in the four-year follow-up. DISCUSSION: Two clinical outcomes are observed. (1) A PEKK telescopic prosthesis can be fabricated using digital workflows, which demonstrates an initial retention value sufficient for intraoral function. (2) No significant wear or decline in the retention force is observed over a four-year follow-up period. CONCLUSIONS: The PEKK telescopic prosthesis facilitated favorable outcomes when restoring extensive mandibular tooth loss. We suggest that PEKK can be effectively used in the fabrication of telescopic prostheses supported by natural teeth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KetonesComputer-Aided DesignMandibleDental Prosthesis DesignTooth LossCrownsFemaleHumansMiddle AgedBenzophenonesPolyether CompoundsPrinting, Three-DimensionalPolymers

Stichwörter der Autor:innen

Digital techniquesPolyetherketoneketoneTelescopic prosthesis

Substanzen

KetonesBenzophenonesPolyether CompoundspolyetherketoneketonePolymers

Autor:innen und Institutionen

  • Department of Prosthodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China.
  • Department of Dental laboratory, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China.
  • Department of Digital Engineering Center of Stomatology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology,Nanjing University, Nanjing, PR China.

Zitieren

APA

Huang, R., Shu, W., Yang, X., Guo, Y., Sun, F., & Wu, G. (2026). Telescopic prosthesis for extensive mandibular tooth loss with a polyetherketoneketone framework fabricated using digital workflow: A case report. Journal of Prosthodontic Research, 70(4), 704-708. https://doi.org/10.2186/jpr.jpr_d_25_00094

Vancouver

Huang R, Shu W, Yang X, Guo Y, Sun F, Wu G. Telescopic prosthesis for extensive mandibular tooth loss with a polyetherketoneketone framework fabricated using digital workflow: A case report. Journal of Prosthodontic Research. 2026;70(4):704-708. doi:10.2186/jpr.jpr_d_25_00094

BibTeX
@article{Huang2026,
  author = {Huang, Rong and Shu, Wen and Yang, Xiaojing and Guo, Yalin and Sun, Fangfang and Wu, Guofeng},
  title = {Telescopic prosthesis for extensive mandibular tooth loss with a polyetherketoneketone framework fabricated using digital workflow: A case report},
  journal = {Journal of Prosthodontic Research},
  year = {2026},
  volume = {70},
  number = {4},
  pages = {704--708},
  doi = {10.2186/jpr.jpr_d_25_00094}
}
Kostenlos starten →