Evaluation of the clinical performance of different occlusal device materials
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.04.021 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Duygucan Pecenek und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Prosthodontics, Institute of Graduate Studies in Health Sciences, Istanbul University, Istanbul, Turkey. Hauptthemen laut MEDLINE: Computer-Aided Design, Occlusal Splints, Dental Materials, Dental Prosthesis Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Istanbul Üniversitesi.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Computer aided technologies have been used to fabricate occlusal devices. However, the clinical behavior of the newly developed materials developed for occlusal devices is unknown. PURPOSE: The purpose of this prospective, double-blind study was to assess the clinical efficacy of recently introduced computer-aided design and computer-aided manufacturing (CAD-CAM) materials for the fabrication of occlusal devices. MATERIAL AND METHODS: A total of 24 participants were divided randomly into 2 study groups; polyetheretherketone (PEEK) and polymethyl methacrylate (PMMA), and a control group (CG). Conventional impressions and gypsum casts were obtained from all participants. In the study groups, the casts were digitalized with an extraoral digital scanner, designed with a software program (Bite Occlusal Device Module; exocad GmbH) and milled from PEEK and PMMA blocks. Clear resin sheets were used for occlusal device fabrication in the CG. The baseline measurements were made during the initial appointments. After 6 months, the participants returned for follow-up evaluations. Clinical performance based on surface roughness, wear of the antagonist teeth, occlusal device fit and therapeutic effect, as well as participant satisfaction were compared using the 1-way ANOVA test between the main groups (α=.05). The post hoc and Kruskal Wallis-H tests were used to compare the nonparametric group. RESULTS: The therapeutic effects of the occlusal devices did not differ. All participants showed improvement in palpation and mandibular movement scores, but no statistically significant differences were found among the groups (P>.05). PEEK and PMMA had statistically less surface wear than CG (P .05). The control group had the best fit (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Department of Prosthodontics, Institute of Graduate Studies in Health Sciences, Istanbul University, Istanbul, Turkey.
- Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey. Electronic address: dongul@istanbul.edu.tr.
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Altınbas University, Istanbul, Turkey.
Förderung
- Istanbul Üniversitesi
Zitieren
APA
Pecenek, D., Gokcen-Rohlig, B., Ongul, D., & Ayvalioglu, D. C. (2025). Evaluation of the clinical performance of different occlusal device materials. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.04.021
Vancouver
Pecenek D, Gokcen-Rohlig B, Ongul D, Ayvalioglu DC. Evaluation of the clinical performance of different occlusal device materials. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.04.021
BibTeX
@article{Pecenek2025,
author = {Pecenek, Duygucan and Gokcen-Rohlig, Bilge and Ongul, Deger and Ayvalioglu, Demet Cagıl},
title = {Evaluation of the clinical performance of different occlusal device materials},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.04.021}
}
EUVIMED