Fatigue performance and failure load of minimally-invasive occlusal veneers made of lithium disilicate and composition-gradient multilayered zirconia: An in vitro study
Journal of Prosthodontic Research · 2025
DOI: 10.2186/jpr.jpr_d_25_00068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2025. Verfasst von Lea S Prott und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany. Hauptthemen laut MEDLINE: Zirconium, Dental Veneers, Dental Porcelain, Dental Restoration Failure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To investigate the effect of ceramic material (lithium disilicate, LDS vs. composition-gradient multilayered zirconia [4Y-PSZ and 5-PSZ], Z) and ceramic layer thickness (0.5 mm, 1.0 mm, and 1.5 mm) on fatigue performance and failure load of occlusal veneers on molars. METHODS: Seventy-two CAD-CAM-fabricated occlusal veneer restorations (IPS e.max CAD; IPS e.max ZirCAD Prime Esthetic, Ivoclar Vivadent) were divided into six groups (n=12, LDS-1.5, LDS-1.0, LDS-0.5; Z-1.5, Z-1.0, Z-0.5). Restorations were adhesively cemented (Variolink Esthetic DC, Ivoclar Vivadent) to dentin-analogue composite dies (Z100, 3M ESPE) and exposed to thermomechanical fatigue (1.2 million cycles, 49 N, 1.6 Hz, 5-55° C). Single-load-to-failure was tested with a universal testing machine. Data were analyzed using ANOVA with Tukey post-hoc tests and t-tests (P 2683 N (LDS-1.0)>2338 N (LDS-1.5)>1744 N (Z-1.5)>1310 N (Z-0.5)>1198 N (Z-1.0). CONCLUSIONS: Ultrathin LDS occlusal veneers outperformed thin and standard thick counterparts, as well as gradient multilayered zirconia veneers at all thickness levels. Ultrathin gradient multilayered zirconia occlusal veneers were prone to cracks during thermomechanical fatigue. Individual mechanical properties need to be considered when aligning the restoration within the multilayered zirconia blank.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.
- Department of Preventive and Restorative Sciences, Penn Dental Medicine, University of Pennsylvania, Philadelphia, USA.
- Institute of Systems Neuroscience, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
- Institute of Neuroscience and Medicine, Brain and Behavior (INM-7), Research Center Jülich, Jülich, Germany.
Zitieren
APA
Prott, L. S., Harlaß, M., Marksteiner, A., Spitznagel, F. A., Langner, R., Zhang, Y., Blatz, M. B., & Gierthmuehlen, P. C. (2025). Fatigue performance and failure load of minimally-invasive occlusal veneers made of lithium disilicate and composition-gradient multilayered zirconia: An in vitro study. Journal of Prosthodontic Research. https://doi.org/10.2186/jpr.jpr_d_25_00068
Vancouver
Prott LS, Harlaß M, Marksteiner A, Spitznagel FA, Langner R, Zhang Y, et al. Fatigue performance and failure load of minimally-invasive occlusal veneers made of lithium disilicate and composition-gradient multilayered zirconia: An in vitro study. Journal of Prosthodontic Research. 2025. doi:10.2186/jpr.jpr_d_25_00068
BibTeX
@article{Prott2025,
author = {Prott, Lea S and Harlaß, Monique and Marksteiner, Alexander and Spitznagel, Frank A and Langner, Robert and Zhang, Yu and Blatz, Markus B and Gierthmuehlen, Petra C},
title = {Fatigue performance and failure load of minimally-invasive occlusal veneers made of lithium disilicate and composition-gradient multilayered zirconia: An in vitro study},
journal = {Journal of Prosthodontic Research},
year = {2025},
doi = {10.2186/jpr.jpr_d_25_00068}
}
EUVIMED