EUVIMEDEUVIMED entdecken
Systematische Übersicht

Influence of ambient light conditions on intraoral scanning: A systematic review

Yun Ma, Yong-Qing Guo, Mohammed Qasem Saleh, Hao Yu

Journal of Prosthodontic Research · 2023 · 68 (2) · 237-245

DOI: 10.2186/jpr.jpr_d_23_00098 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Prosthodontic Research, 2023. Verfasst von Yun Ma und 3 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian …. Hauptthemen laut MEDLINE: Light. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To systematically assess the influence of ambient light on the accuracy and scanning time of intraoral scanning. STUDY SELECTION: The present systematic review (CRD 42022346672) was registered at the International Prospective Register of Systematic Reviews (PROSPERO) and was performed based on the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020. Electronic searches were conducted using PubMed, Web of Science, and EMBASE, complemented by gray literature, references, and citations of the included studies. The primary outcome was accuracy, and the scanning time was a secondary outcome. Owing to the high heterogeneity, the pooled data were analyzed descriptively. RESULTS: Six in vitro and two in vivo experiments were performed. Three in vitro studies reported both the accuracy and scanning time of the intraoral scans, whereas the remaining studies exclusively evaluated the accuracy. The studies mainly investigated the influence of illumination levels (0-11000 lux) on intraoral scanning. Intraoral scans revealed optimal accuracy at 1000-lux illumination for complete-arch dentition scans, whereas the influence of illumination levels on 4-unit or shorter scans was not clinically significant. The intraoral scans obtained using confocal microscopy were less affected by the illumination levels than those obtained using the active triangulation technique. Furthermore, the scanning time tended to increase with increasing illumination. CONCLUSIONS: Evidently from the limited number of studies conducted, ambient light illumination had considerable influence on the accuracy and scanning time of intraoral scanning, which appeared to be related to the scanning range and imaging technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LightHumansMicroscopy, ConfocalLightingTime FactorsImaging, Three-Dimensional

Stichwörter der Autor:innen

AccuracyColor temperatureIlluminationIntraoral scannerScanning time

Autor:innen und Institutionen

  • Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Med…
  • Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, Fuzhou, China.
  • Department of Applied Prosthodontics Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.

Zitieren

APA

Ma, Y., Guo, Y. Q., Saleh, M. Q., & Yu, H. (2023). Influence of ambient light conditions on intraoral scanning: A systematic review. Journal of Prosthodontic Research, 68(2), 237-245. https://doi.org/10.2186/jpr.jpr_d_23_00098

Vancouver

Ma Y, Guo YQ, Saleh MQ, Yu H. Influence of ambient light conditions on intraoral scanning: A systematic review. Journal of Prosthodontic Research. 2023;68(2):237-245. doi:10.2186/jpr.jpr_d_23_00098

BibTeX
@article{Ma2023,
  author = {Ma, Yun and Guo, Yong-Qing and Saleh, Mohammed Qasem and Yu, Hao},
  title = {Influence of ambient light conditions on intraoral scanning: A systematic review},
  journal = {Journal of Prosthodontic Research},
  year = {2023},
  volume = {68},
  number = {2},
  pages = {237--245},
  doi = {10.2186/jpr.jpr_d_23_00098}
}
Kostenlos starten →