EUVIMEDEUVIMED entdecken
Crossref

ANALYSIS OF THERMAL PROTECTIVE PERFORMANCE OF ALUMINUM FOIL INSULATION SUITS DUE TO VARIATIONS IN AIR GAP THICKNESS

Kiemas Aji Andika Mahendra, Slamet Wahyudi, Eko Siswanto, Jiafeng Yao

International Journal of Mechanical Engineering Technologies and Applications · 23.06.2025 · 6 (2) · 202-210

DOI: 10.21776/mechta.2025.006.02.4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Mechanical Engineering Technologies and Applications, online erschienen am 23.06.2025. Verfasst von Kiemas Aji Andika Mahendra und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates improving the thermal protective performance (TPP) of aluminum foil insulation suit by incorporating air gaps to reduce heat transfer. Firefighters rely on personal protective equipment that must meet NFPA 1971 standards, requiring a minimum TPP of 35 cal/cm². Using a heat transfer bench scale test, three-layer aluminum foil insulation suits with air gaps ranging from 0 mm to 7.68 mm were tested. Each sample was exposed to heat until the innermost layer reached 55°C. The analysis of temperature, heat transfer rate, heat flux, second-degree burn time, and thermal resistance revealed that a TPP exceeding 35 cal/cm² was achieved at a 6.4 mm air gap, peaking at 36.30 cal/cm² at 7.68 mm. The increase in TPP with larger air gaps was due to higher thermal resistance and extended burn times. Thus, a minimum air gap of 6.4 mm is recommended for firefighter clothing to meet safety standards.

Zitieren

APA

Mahendra, K. A. A., Wahyudi, S., Siswanto, E., & Yao, J. (2025). ANALYSIS OF THERMAL PROTECTIVE PERFORMANCE OF ALUMINUM FOIL INSULATION SUITS DUE TO VARIATIONS IN AIR GAP THICKNESS. International Journal of Mechanical Engineering Technologies and Applications, 6(2), 202-210. https://doi.org/10.21776/mechta.2025.006.02.4

Vancouver

Mahendra KAA, Wahyudi S, Siswanto E, Yao J. ANALYSIS OF THERMAL PROTECTIVE PERFORMANCE OF ALUMINUM FOIL INSULATION SUITS DUE TO VARIATIONS IN AIR GAP THICKNESS. International Journal of Mechanical Engineering Technologies and Applications. 2025;6(2):202-210. doi:10.21776/mechta.2025.006.02.4

BibTeX
@article{Mahendra2025,
  author = {Mahendra, Kiemas Aji Andika and Wahyudi, Slamet and Siswanto, Eko and Yao, Jiafeng},
  title = {ANALYSIS OF THERMAL PROTECTIVE PERFORMANCE OF ALUMINUM FOIL INSULATION SUITS DUE TO VARIATIONS IN AIR GAP THICKNESS},
  journal = {International Journal of Mechanical Engineering Technologies and Applications},
  year = {2025},
  volume = {6},
  number = {2},
  pages = {202--210},
  doi = {10.21776/mechta.2025.006.02.4}
}
Kostenlos starten →