Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions
IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 7700605-7700605
DOI: 10.1109/tasc.2026.3690164 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Hirofumi Watanabe und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: JSPS KAKENHI, Chubu University, Chubu University Frontier Research Institute Grant.
Abstract (Originalsprache)
Thermal insulation performance of three different multilayer insulation (MLI) wrapping methods was investigated using a vertical guarded boil-off calorimeter to determine the method that minimizes both the heat leak and the wrapping effort for cryogenic pipes used in superconducting power transmission. The wrapping methods are termed the Swiss-roll type, alternating-seam type, and blanket type. In the Swiss-roll type, a single MLI film is rolled continuously around the liquid nitrogen tank in the calorimeter from the room-temperature side to the cryogenic-temperature side. In the alternating-seam type, MLI films are wrapped layer by layer around the tank, while their seams are placed alternately on opposite sides of the tank. In the blanket type, MLI films are stacked to form a single blanket, which is then wrapped around the tank. Heat leak measurements for these methods indicate that the Swiss-roll type is the most effective, considering both thermal insulation performance and workability. For the Swiss-roll type, the dependence of heat leak on wrapping strength was also investigated using a horizontal guarded boil-off calorimeter by varying the circumferential length of the MLI. The results reveal that as the wrapping became looser, the heat leak decreased significantly until a certain wrapping strength, at which a space clearly formed beneath the tank, was reached. Beyond this wrapping strength, the heat leak remained nearly constant. These findings show that an optimum wrapping strength, which minimizes both the heat leak and wrapping effort, exists in the Swiss-roll type method.
Förderung
- JSPS KAKENHI
- Chubu University
- Chubu University Frontier Research Institute Grant
- JFE Steel Corporation
Zitieren
APA
Watanabe, H., Otsuka, M., Kobayashi, H., Kato, K., Kobayashi, T., Shiomi, T., Kanda, M., & Yamaguchi, S. (2026). Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions. IEEE Transactions on Applied Superconductivity, 36(5), 7700605-7700605. https://doi.org/10.1109/tasc.2026.3690164
Vancouver
Watanabe H, Otsuka M, Kobayashi H, Kato K, Kobayashi T, Shiomi T, et al. Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions. IEEE Transactions on Applied Superconductivity. 2026;36(5):7700605-7700605. doi:10.1109/tasc.2026.3690164
BibTeX
@article{Watanabe2026,
author = {Watanabe, Hirofumi and Otsuka, Makoto and Kobayashi, Hiroaki and Kato, Koshi and Kobayashi, Toya and Shiomi, Takaya and Kanda, Masae and Yamaguchi, Sataro},
title = {Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions},
journal = {IEEE Transactions on Applied Superconductivity},
year = {2026},
volume = {36},
number = {5},
pages = {7700605--7700605},
doi = {10.1109/tasc.2026.3690164}
}
EUVIMED