EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery

Banu Acar, Isil M Torun, Suphi Acar

The Open Ophthalmology Journal · 14.06.2018 · 12 (1) · 94-103

DOI: 10.2174/1874364101812010094 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Open Ophthalmology Journal, erschienen am 14.06.2018. Verfasst von Banu Acar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Bati Goz Hospital, Istanbul, Turkey. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Advancements in cataract surgery have necessitated the availability of intraocular lens preloaded delivery systems that can safely, effectively and predictably deliver IOLs in the eye. Preloaded delivery systems simplify and reduce procedural variability during surgery preparation.

Objective

The objective of this study was to evaluate clinical acceptability, delivery characteristics and clinical outcomes in patients implanted with new generation hydrophobic acrylic Intraocular Lens with Preloaded delivery system.

Methods

This was a single centre retrospective study. Total 41 patients were enrolled in the study to get at least 38 patients for evaluation. All patients were assessed on day1 and 1, 3 and 6 months after surgery.

Results

EYECRYL-SERT showed ‘excellent’ ease of insertion and handling in all 41(100%) patients. Corrected Distance Visual Acuity (CDVA) improved from 0.74±0.58 logMAR during screening to 0.03±0.04 logMAR 6 months after surgery. The Corrected Intermediate Visual Acuity (CIVA) and Corrected Near Visual Acuity (CNVA) were 0.10±0.04 and 0.01±0.02 logMAR post 6 months surgery, respectively. The refractive spherical equivalence was -1.94±2.51 D during screening, which improved significantly (p=0.0018) to -0.21±0.47 D post 6 months surgery. The low and high contrast sensitivity was 0.06±0.06 and -0.05±0.06 logMAR after 6 months surgery, respectively. The endothelial cell loss was 5.67%, 7.22% and 9.75% at 1, 3, and 6 months after surgery, respectively, as compared to screening. None of the subjects reported any adverse event during the study period.

Conclusion

The IOL delivery system (EYECRYL_SERT) provided desired delivery characteristics during cataract surgery and was effective in improving clinical outcomes in cataract patients.

Schlagwörter

Stichwörter der Autor:innen

Cataract surgeryContrast sensitivityHydrophobic IOLIOLPreloaded delivery systemVisual acuity

Autor:innen und Institutionen

  • Bati Goz Hospital, Istanbul, Turkey.
  • Igdir State Hospital, Ophthalmology Clinic, Merkez, Igdir, Turkey.

Zitieren

APA

Acar, B., Torun, I. M., & Acar, S. (2018). Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. The Open Ophthalmology Journal, 12(1), 94-103. https://doi.org/10.2174/1874364101812010094

Vancouver

Acar B, Torun IM, Acar S. Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. The Open Ophthalmology Journal. 2018;12(1):94-103. doi:10.2174/1874364101812010094

BibTeX
@article{Acar2018,
  author = {Acar, Banu and Torun, Isil M and Acar, Suphi},
  title = {Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery},
  journal = {The Open Ophthalmology Journal},
  year = {2018},
  volume = {12},
  number = {1},
  pages = {94--103},
  doi = {10.2174/1874364101812010094}
}
Kostenlos starten →