Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery
The Open Ophthalmology Journal · 14.06.2018 · 12 (1) · 94-103
DOI: 10.2174/1874364101812010094 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Open Ophthalmology Journal, erschienen am 14.06.2018. Verfasst von Banu Acar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Bati Goz Hospital, Istanbul, Turkey. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Advancements in cataract surgery have necessitated the availability of intraocular lens preloaded delivery systems that can safely, effectively and predictably deliver IOLs in the eye. Preloaded delivery systems simplify and reduce procedural variability during surgery preparation.
Objective
The objective of this study was to evaluate clinical acceptability, delivery characteristics and clinical outcomes in patients implanted with new generation hydrophobic acrylic Intraocular Lens with Preloaded delivery system.
Methods
This was a single centre retrospective study. Total 41 patients were enrolled in the study to get at least 38 patients for evaluation. All patients were assessed on day1 and 1, 3 and 6 months after surgery.
Results
EYECRYL-SERT showed ‘excellent’ ease of insertion and handling in all 41(100%) patients. Corrected Distance Visual Acuity (CDVA) improved from 0.74±0.58 logMAR during screening to 0.03±0.04 logMAR 6 months after surgery. The Corrected Intermediate Visual Acuity (CIVA) and Corrected Near Visual Acuity (CNVA) were 0.10±0.04 and 0.01±0.02 logMAR post 6 months surgery, respectively. The refractive spherical equivalence was -1.94±2.51 D during screening, which improved significantly (p=0.0018) to -0.21±0.47 D post 6 months surgery. The low and high contrast sensitivity was 0.06±0.06 and -0.05±0.06 logMAR after 6 months surgery, respectively. The endothelial cell loss was 5.67%, 7.22% and 9.75% at 1, 3, and 6 months after surgery, respectively, as compared to screening. None of the subjects reported any adverse event during the study period.
Conclusion
The IOL delivery system (EYECRYL_SERT) provided desired delivery characteristics during cataract surgery and was effective in improving clinical outcomes in cataract patients.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Bati Goz Hospital, Istanbul, Turkey.
- Igdir State Hospital, Ophthalmology Clinic, Merkez, Igdir, Turkey.
Zitieren
APA
Acar, B., Torun, I. M., & Acar, S. (2018). Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. The Open Ophthalmology Journal, 12(1), 94-103. https://doi.org/10.2174/1874364101812010094
Vancouver
Acar B, Torun IM, Acar S. Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. The Open Ophthalmology Journal. 2018;12(1):94-103. doi:10.2174/1874364101812010094
BibTeX
@article{Acar2018,
author = {Acar, Banu and Torun, Isil M and Acar, Suphi},
title = {Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery},
journal = {The Open Ophthalmology Journal},
year = {2018},
volume = {12},
number = {1},
pages = {94--103},
doi = {10.2174/1874364101812010094}
}