EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study of the combined effect of temperature and free chlorine concentration on the chlorine bulk decay coefficient in water supply systems

Rojacques Mompremier, Héctor Hugo León Santiesteban, Jorge Ramírez Muñoz, Jersain Gómez Núñez

Water Supply · 01.12.2024 · 24 (12) · 4046-4058

DOI: 10.2166/ws.2024.255 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Supply, online erschienen am 11.12.2024. Verfasst von Rojacques Mompremier und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The chlorine bulk decay coefficient (kb) is a crucial parameter for modeling the chlorine decay process within drinking water distribution systems. In this study, the combined effect of temperature and chlorine concentration on kb was investigated. A central composite design (CCD) was employed. Ten scenarios were conducted on a pilot-scale pipeline network with initial chlorine concentrations from 0.38 to 4.62 mg/L and water temperature from 22.93 to 37.07 °C. A statistical analysis of the kb obtained in the experiments was conducted using STATGRAPHICS software. An analysis of variance (ANOVA) for Log10(kb) was also performed to segregate the combined contributions of chlorine and temperature effects. Chlorine concentration and temperature are factors that significantly affect kb. However, the temperature effect is marginal compared to that of the chlorine concentration. A quadratic model obtained from CCD data effectively predicted the kb within the proposed experimental zone, although its utility may be limited at lower temperatures. The combined effect of chlorine concentration and temperature on the Log10(kb) is shown on the response surface obtained from the quadratic prediction model of kb. Analysis of the response surface revealed that the operating conditions of 22.3 °C and 3.33 mg/L, respectively, yield the minimal value of kb = 0.0347 h−1.

Zitieren

APA

Mompremier, R., Santiesteban, H. H. L., Muñoz, J. R., & Núñez, J. G. (2024). Study of the combined effect of temperature and free chlorine concentration on the chlorine bulk decay coefficient in water supply systems. Water Supply, 24(12), 4046-4058. https://doi.org/10.2166/ws.2024.255

Vancouver

Mompremier R, Santiesteban HHL, Muñoz JR, Núñez JG. Study of the combined effect of temperature and free chlorine concentration on the chlorine bulk decay coefficient in water supply systems. Water Supply. 2024;24(12):4046-4058. doi:10.2166/ws.2024.255

BibTeX
@article{Mompremier2024,
  author = {Mompremier, Rojacques and Santiesteban, Héctor Hugo León and Muñoz, Jorge Ramírez and Núñez, Jersain Gómez},
  title = {Study of the combined effect of temperature and free chlorine concentration on the chlorine bulk decay coefficient in water supply systems},
  journal = {Water Supply},
  year = {2024},
  volume = {24},
  number = {12},
  pages = {4046--4058},
  doi = {10.2166/ws.2024.255}
}
Kostenlos starten →