The Effect of Donor Packed Cell Volume and Storage Characteristics on Transfusion Efficacy in Cats
Veterinary Medicine: Research and Reports · 2026-09 · Volume 17 · 1-7
DOI: 10.2147/vmrr.s620894 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Medicine: Research and Reports, 2026-09. Verfasst von Brynna Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Emergency and Critical Care Department, Schwarzman Animal Medical Center, New York, NY, USA. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Purpose
To determine whether donor packed cell volume (PCV) and storage-related changes in feline packed red blood cell (pRBC) units influence transfusion efficacy in cats. Patients and Methods: In this prospective, observational study, 35 client-owned, transfusion-naïve, anemic cats that received a single pRBC transfusion during hospitalization were enrolled. Donor unit characteristics including age, PCV, total solids, potassium, and ammonia were measured prior to transfusion. Transfusion response was assessed as the change in recipient PCV, normalized to transfusion dose (mL/kg), measured immediately post-transfusion and at 12 and 24 hours post-transfusion. Transfusion efficacy was assessed as the change in recipient PCV at each timepoint.
Results
Dose-normalized response was available for 34 cats immediately post-transfusion, 30 cats at 12 hours, and 16 cats at 24 hours. Median recipient pre-transfusion PCV (17%) increased significantly at all post-transfusion timepoints (T0: 21%, T12: 23%, T24: 24%; p≤,0.002). Increasing donor unit age was associated with higher ammonia concentrations and lower donor unit PCV but not with potassium concentration. No significant associations were identified between donor unit characteristics and transfusion efficacy.
Conclusion
Transfusion of pRBCs in cats resulted in rapid and sustained increase in recipient PCV. No association was detected between donor unit PCV or storage-related characteristics and the magnitude of this response. These findings suggest that transfusion response is multifactorial and may reflect a combination of donor-, product-, and recipient-related factors.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emergency and Critical Care Department, Schwarzman Animal Medical Center, New York, NY, USA.
ORCID-Profile: Brynna Lee, Joel G Weltman
Zitieren
APA
Lee, B., Chambers, K., Wendth, R., Prittie, J., Mastrocco, A., & Weltman, J. G. (2026). The Effect of Donor Packed Cell Volume and Storage Characteristics on Transfusion Efficacy in Cats. Veterinary Medicine: Research and Reports, Volume 17, 1-7. https://doi.org/10.2147/vmrr.s620894
Vancouver
Lee B, Chambers K, Wendth R, Prittie J, Mastrocco A, Weltman JG. The Effect of Donor Packed Cell Volume and Storage Characteristics on Transfusion Efficacy in Cats. Veterinary Medicine: Research and Reports. 2026;Volume 17:1-7. doi:10.2147/vmrr.s620894
BibTeX
@article{Lee2026,
author = {Lee, Brynna and Chambers, Kelly and Wendth, Rebecca and Prittie, Jennifer and Mastrocco, Alicia and Weltman, Joel G},
title = {The Effect of Donor Packed Cell Volume and Storage Characteristics on Transfusion Efficacy in Cats},
journal = {Veterinary Medicine: Research and Reports},
year = {2026},
volume = {Volume 17},
pages = {1--7},
doi = {10.2147/vmrr.s620894}
}
EUVIMED