In-silico modeling of induction heating of hip endoprostheses for facilitated intentional removal

Patrick Evers, Nürnberger, Florian, Herbst, Sebastian, Magnus Reulbach, Jakubowitz, Elke

Publikationsserver der Technischen Universität Clausthal · 01.01.2025

DOI: 10.21268/20250506-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Publikationsserver der Technischen Universität Clausthal, erschienen am 01.01.2025. Verfasst von Patrick Evers und 7 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In OECD countries, infections and loosening are the main reasons for revision surgeries in total hip arthroplasties (THA), accounting for about 10% of all THA procedures. The traditional method for implant removal is purely mechanical, involving chiseling and grinding to remove bone cement, which subjects the surrounding tissue to significant stress and poses a high risk of femoral fractures. A novel approach to tissue-conserving hip arthroplasty removal is the use of induction heating to weaken the interface between metallic implants and bone cement. An alternating electromagnetic field is applied transcutaneously, heating the implant's surface. For cemented arthroplasties, this heat softens the thermoplastic bone cement, releasing the metallic implant and allowing the cement to detach from the bone, facilitating removal. Precise control of the heat input and its duration are essential to minimize thermal damage to surrounding tissues. To predict the surface temperatures resulting from inductive heating of the paramagnetic implant material Co-28Cr-6Mo, an in-silico model was developed using Ansys Mechanical. This model will assist in designing inductors and heating strategies for precise and homogeneous heating at the implant-to-bone-cement interface. For this model, electromagnetic and thermal properties of the metallic implants were characterized, measuring thermal conduction coefficients and specific heat capacities.

Schlagwörter

induction heatingtotal hip arthroplastyimplant removalbone cementCoCrMo alloyimplant looseningreoperationfemoral fractureelectromagnetic simulationspecific heat

Zitieren

APA

Evers, P., Nürnberger, Florian, Herbst, Sebastian, Reulbach, M., Jakubowitz, & Elke (2025). In-silico modeling of induction heating of hip endoprostheses for facilitated intentional removal. Publikationsserver der Technischen Universität Clausthal. https://doi.org/10.21268/20250506-4

Vancouver

Evers P, Nürnberger, Florian, Herbst, Sebastian, Reulbach M, et al. In-silico modeling of induction heating of hip endoprostheses for facilitated intentional removal. Publikationsserver der Technischen Universität Clausthal. 2025. doi:10.21268/20250506-4

BibTeX
@article{Evers2025,
  author = {Evers, Patrick and Nürnberger and Florian and Herbst and Sebastian and Reulbach, Magnus and Jakubowitz and Elke},
  title = {In-silico modeling of induction heating of hip endoprostheses for facilitated intentional removal},
  journal = {Publikationsserver der Technischen Universität Clausthal},
  year = {2025},
  doi = {10.21268/20250506-4}
}
Kostenlos starten →