Evaluation of Oxinium (Oxidized Zr2.5Nb) Femoral Heads in Hip Endoprostheses—Case Report

Boštjan Kocjančič, Ema Kocjančič, Špela Tadel Kocjančič, Janez Kovač, Monika Jenko, Mojca Debeljak

Coatings · 16.09.2025 · 15 (9) · 1087

DOI: 10.3390/coatings15091087 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Coatings, online erschienen am 16.09.2025. Verfasst von Boštjan Kocjančič und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian Research Agency, Department of Orthopaedic Surgery of University Medical Centre Ljubljana, Slovenia—UMC Tertiary project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Total hip arthroplasty (THA) is a widely performed and successful surgical treatment for degenerative joint disease. With increasing use in younger and more active patients, the demand for durable, biocompatible, and low-wear implant materials has grown. Oxidized zirconium (Oxinium, Zr2.5Nb) was introduced as a promising femoral head material, combining the strength of metal with the low-friction properties of ceramic. Despite encouraging early results, clinical reports have documented complications including head wear, especially after dislocation, and metallosis. We present the case of a 64-year-old male who underwent primary THA in 2009 and required revision in 2021 due to severe metallosis. Notably, no dislocation was observed that could explain the damage to the Oxinium head. Surface and subsurface analyses using X-ray photoelectron spectroscopy (XPS) and micro-indentation hardness testing revealed wear and deformation inconsistent with Oxinium’s anticipated durability. These findings highlight the importance of the femoral head–polyethylene liner interface in implant longevity. Although Oxinium–XLPE articulations remain promising, risks such as damage to the femoral head, liner dislocation, impingement, and metallosis must be carefully considered. Surgical technique, liner placement, and locking mechanisms play critical roles in preventing failure. Further biomechanical and clinical studies are needed to optimize implant design and improve long-term outcomes.

Förderung

  • Slovenian Research Agency
  • Department of Orthopaedic Surgery of University Medical Centre Ljubljana, Slovenia—UMC Tertiary project

Zitieren

APA

Kocjančič, B., Kocjančič, E., Kocjančič, Š. T., Kovač, J., Jenko, M., & Debeljak, M. (2025). Evaluation of Oxinium (Oxidized Zr2.5Nb) Femoral Heads in Hip Endoprostheses—Case Report. Coatings, 15(9), 1087. https://doi.org/10.3390/coatings15091087

Vancouver

Kocjančič B, Kocjančič E, Kocjančič ŠT, Kovač J, Jenko M, Debeljak M. Evaluation of Oxinium (Oxidized Zr2.5Nb) Femoral Heads in Hip Endoprostheses—Case Report. Coatings. 2025;15(9):1087. doi:10.3390/coatings15091087

BibTeX
@article{Kocjani2025,
  author = {Kocjančič, Boštjan and Kocjančič, Ema and Kocjančič, Špela Tadel and Kovač, Janez and Jenko, Monika and Debeljak, Mojca},
  title = {Evaluation of Oxinium (Oxidized Zr2.5Nb) Femoral Heads in Hip Endoprostheses—Case Report},
  journal = {Coatings},
  year = {2025},
  volume = {15},
  number = {9},
  pages = {1087},
  doi = {10.3390/coatings15091087}
}
Kostenlos starten →