EUVIMEDEUVIMED entdecken
Crossref

Optimizing Muscle-Tendon Lengths in Reverse Total Shoulder Arthroplasty

Jay M Levin iD, Fabrizio Gobbi iD, Marcus G Pandy, Giovanni Di Giacomo iD, Mark A Frankle iD

Journal of Bone and Joint Surgery · 2024

DOI: 10.2106/jbjs.23.01123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bone and Joint Surgery, 2024. Verfasst von Jay M Levin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Prosthesis Design, Shoulder Joint. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Optimizing the function of muscles that cross the glenohumeral articulation in reverse total shoulder arthroplasty (RTSA) is controversial. The current study used a geometric model of the shoulder to systematically examine surgical placement and implant-design parameters to determine which RTSA configuration most closely reproduces native muscle-tendon lengths of the deltoid and rotator cuff.

Methods

A geometric model of the glenohumeral joint was developed and adjusted to represent small, medium, and large shoulders. Muscle-tendon lengths were assessed for the anterior deltoid, middle deltoid, posterior deltoid, and supraspinatus from 0 to 90° of scaption; for the subscapularis from 0° to 60° of internal rotation (IR) and 0° to 60° of scaption; for the infraspinatus from 0° to 60° of external rotation (ER) and 0° to 60° of scaption; and for the teres minor from 0° to 60° of ER at 90° of scaption. RTSA designs were virtually implanted using the following parameters: (1) surgical placement with a centered or inferior glenosphere position and a humeral offset of 0, 5, or 10 mm relative to the anatomic neck plane, (2) implant design involving a glenosphere size of 30, 36, or 42 mm, glenosphere lateralization of 0, 5, or 10 mm, and humeral neck-shaft angle of 135°, 145°, or 155°. Thus, 486 RTSA-shoulder size combinations were analyzed. Linear regression assessed the strength of association between parameters and the change in each muscle-tendon length from the native length.

Results

The configuration that most closely restored anatomic muscle-tendon lengths in a small shoulder was a 30-mm glenosphere with a centered position, 5 mm of glenoid lateralization, 0 mm of humeral offset, and a 135° neck-shaft angle. For a medium shoulder, the corresponding combination was 36 mm, centered, 5 mm, 0 mm, and 135°. For a large shoulder, it was 30 mm, centered, 10 mm, 0 mm, and 135°. The most important implant-design parameter associated with restoration of native muscle-tendon lengths was the neck-shaft angle, with a 135° neck-shaft angle being favored (β = 0.568 to 0.657, p < 0.001). The most important surgical parameter associated with restoration of native muscle-tendon lengths was humeral offset, with a humeral socket placed at the anatomic neck plane being favored (β = 0.441 to 0.535, p < 0.001).

Conclusions

A combination of a smaller, lateralized glenosphere, a humeral socket placed at the anatomic neck plane, and an anatomic 135° neck-shaft angle best restored native deltoid and rotator cuff muscle-tendon lengths in RTSA. Clinical Relevance: This study of surgical and implant factors in RTSA highlighted optimal configurations for restoration of native muscle-tendon lengths of the deltoid and rotator cuff, which has direct implications for surgical technique and implant selection. Additionally, it demonstrated the most influential surgical and implant factors with respect to muscle-tendon lengths, which can be used to aid intraoperative decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderProsthesis DesignShoulder JointHumansShoulder ProsthesisTendonsRotator CuffModels, AnatomicRange of Motion, ArticularMuscle, SkeletalDeltoid Muscle

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina.
  • Department of Orthopaedic Surgery, Concordia Hospital, Rome, Italy.
  • Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, Australia.
  • Shoulder and Elbow Specialty, Florida Orthopaedic Institute, Tampa, Florida.

ORCID-Profile: Jay M Levin, Fabrizio Gobbi, Giovanni Di Giacomo, Mark A Frankle

Zitieren

APA

Levin, J. M., Gobbi, F., Pandy, M. G., Di Giacomo, G., & Frankle, M. A. (2024). Optimizing Muscle-Tendon Lengths in Reverse Total Shoulder Arthroplasty. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.23.01123

Vancouver

Levin JM, Gobbi F, Pandy MG, Di Giacomo G, Frankle MA. Optimizing Muscle-Tendon Lengths in Reverse Total Shoulder Arthroplasty. Journal of Bone and Joint Surgery. 2024. doi:10.2106/jbjs.23.01123

BibTeX
@article{Levin2024,
  author = {Levin, Jay M and Gobbi, Fabrizio and Pandy, Marcus G and Di Giacomo, Giovanni and Frankle, Mark A},
  title = {Optimizing Muscle-Tendon Lengths in Reverse Total Shoulder Arthroplasty},
  journal = {Journal of Bone and Joint Surgery},
  year = {2024},
  doi = {10.2106/jbjs.23.01123}
}
Kostenlos starten →